精彩推荐

数控机床电气调试必备软件全解析(2026版)-CNCShare | 数控电气技术中心
共享屋-CNCShare | 数控电气技术中心
数控机床电气工程师成长历程-CNCShare | 数控电气技术中心
共享屋积分与会员功能介绍-CNCShare | 数控电气技术中心
问题与反馈-CNCShare | 数控电气技术中心
最新发布第23页
Fanuc M19 Spindle Orientation: Parameter 4077 Angle Formula, 3117#1 and Diagnostics 445/449-CNCShare | 数控电气技术中心

Fanuc M19 Spindle Orientation: Parameter 4077 Angle Formula, 3117#1 and Diagnostics 445/449

When M19 stops at the wrong angle, the value to change is 4077 - but it holds an offset count relative to the one-turn signal, not degrees. Verified formula (4096 counts/rev, 0.087...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
03910
FANUC 数据备份与恢复完整教程:ALL I/O 全备份 / BOOT SRAM 备份 三套方法对比与恢复实操-CNCShare | 数控电气技术中心

FANUC 数据备份与恢复完整教程:ALL I/O 全备份 / BOOT SRAM 备份 三套方法对比与恢复实操

FANUC 数据备份三套方法怎么选:ALL I/O 一键全备份(0020/0313#0/0138#0,断电重启后自动补输出 SRAM 与用户文件)、BOOT 画面 SRAM 备份(SRAM_BAK.001,系统起不来时唯一可用手段)、分项备...
发那科梯形图 Y输出上电全为0排查 FANUC Ladder-CNCShare | 数控电气技术中心

发那科梯形图 Y输出上电全为0排查 FANUC Ladder

发那科梯形图故障排查:FANUC Ladder III 环境下机床上电后 Y 输出全部为 0 的六个排查方向,涵盖 PMC 运行状态、I/O 电源与保险、模式开关、地址分配、梯形图逻辑与外部中间继电器,附 X/Y 同...
How to Troubleshoot I/O Link & PROFIBUS Station Dropout: Reading ER97 + the I/O Link Chain Rule + PROFIBUS BF LED Diagnosis + Terminator/Address/Shielding Checklist-CNCShare | 数控电气技术中心

How to Troubleshoot I/O Link & PROFIBUS Station Dropout: Reading ER97 + the I/O Link Chain Rule + PROFIBUS BF LED Diagnosis + Terminator/Address/Shielding Checklist

Do not swap modules the moment a station drops. FANUC I/O Link is a daisy chain: one break takes out everything downstream, so the station named in the alarm is usually not the fau...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare10天前
07210
FANUC 0i-Mate / 0i-D Alarm Quick Reference: Same Number, Different Meaning + FSSB 5134-5198 and Serial Spindle 749/750-CNCShare | 数控电气技术中心

FANUC 0i-Mate / 0i-D Alarm Quick Reference: Same Number, Different Meaning + FSSB 5134-5198 and Serial Spindle 749/750

FANUC 0i / 0i-Mate alarm quick reference: on the old 0 series 950 is a +24V fuse while on 0i it is a PMC system alarm (24V moved to 960); FSSB 5134-5198 and serial spindle 749/750 ...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
05310
CNC Alarm Message Chinese Reference: 120 Common English Phrases and a 30-Second Triage Method-CNCShare | 数控电气技术中心

CNC Alarm Message Chinese Reference: 120 Common English Phrases and a 30-Second Triage Method

Translating an English alarm is only the first step. This page groups 120 common field phrasings by subsystem with Chinese meanings, maps keywords such as NOT READY, OVERLOAD, FAUL...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
05510
Fanuc E-Stop Circuit: G8.4, X8.4 Signals and Why the Servo Is Not Ready-CNCShare | 数控电气技术中心

Fanuc E-Stop Circuit: G8.4, X8.4 Signals and Why the Servo Is Not Ready

Releasing the E-stop does not bring the servo back, and the control often gives no alarm number. Walks the four-layer chain: 24V safety loop, X8.4, G8.4, SA / MCC / CX4, with an X-...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare昨天
06310
Sinumerik F-Code Cross-Reference: F300xx / F0xxx / A3xxx Mapped to 230xxx Display Numbers-CNCShare | 数控电气技术中心

Sinumerik F-Code Cross-Reference: F300xx / F0xxx / A3xxx Mapped to 230xxx Display Numbers

The manual calls it F30020, a 828D screen shows 230020 - one fault, two numbering systems. This table maps SINAMICS F codes to 828D/840D sl display numbers, fault meanings and firs...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare前天
04010
FANUC MF PLUS维修案例:SV0436报警反复出现故障排查与根治方案-CNCShare | 数控电气技术中心

FANUC MF PLUS维修案例:SV0436报警反复出现故障排查与根治方案

本文分享FANUC MF PLUS数控系统SV0436伺服过载报警反复出现的维修案例,详细阐述故障现象、排查流程、关键问题定位及根治方案,为数控维修人员提供专业技术参考,解决MF Plus系统同类故障难题。
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare21天前
021610
FANUC 0TD 系统断电后车床无法起动故障维修案例 | FTC-20 数控车床参数丢失恢复方法-CNCShare | 数控电气技术中心

FANUC 0TD 系统断电后车床无法起动故障维修案例 | FTC-20 数控车床参数丢失恢复方法

本文详细介绍 CNC FTC—20 数控车床(FANUC 0TD 系统)在外部断电后出现 CRT 乱点、操作面板失灵、X/Z 轴参数报警的维修过程,重点讲解 MEM-A4 记忆板更换与机械参数重新输入步骤。