排序
HEIDENHAIN TNC Block Quick Reference: BEGIN/BLK FORM/TOOL CALL/L/C/CR/APPR/CYCL DEF
The most-used HEIDENHAIN TNC Klartext blocks compressed onto one page - the 8-step program layout, a full block table, motion elements (R0/RL/RR, DR, I) and common M codes. For wri...
HEIDENHAIN TNC Conversational Programming for Beginners: One Minimal Program
HEIDENHAIN Klartext is conversational programming - the screen asks, you answer, no G-code memorising. Using a 13-line minimal program, this explains BEGIN PGM, BLK FORM blank, TOO...
HEIDENHAIN iTNC 530 vs TNC 620 / 640 / TNC7: Differences, MP vs Cfg, and Program Migration
iTNC 530 uses MP machine parameters while TNC 620/640/TNC7 use structured Cfg objects — the first divide in any retrofit or upgrade. This guide uses official HEIDENHAIN data for g...
FANUC Acceleration/Deceleration and Corner Slowdown: 1620 Rapid, 1622 Cutting, and the Trade-offs
Parameter 1620 governs rapid-traverse accel/decel and 1622 governs cutting-feed accel/decel, both in msec; 1610 selects exponential, linear or bell-shaped and 1621 sets bell T2. Th...
FANUC AICC / Nano Smoothing Setup: G05.1 Q1, Parameter-Side Enable, and Six Reasons It Does Nothing
G05.1 Q1 turns on high-speed high-precision contour control and Q0 cancels it, but the G-code alone is not enough. This guide covers the PRMTUN high-precision setup path, checking ...
SINUMERIK 828D Cycle Alarms 61000 / 62000 / 65xxx: How to Read and Fix Them
On an 828D, 61000/62000 are shorthand for the six-digit 06xxxx cycle-alarm range; 065000-069999 belongs to user cycles triggered by SETAL. This guide gives the segment rules, alarm...
SINUMERIK 840D/828D UAFEHL Alarm: What It Means, Why the PLC Stops, and How to Localize It via DB2
UAFEHL is not a specific fault — it is the SINUMERIK flag for 'a user alarm triggered the PLC stop.' Six root-cause families, a 5-step localization procedure, SF/STOP/RUN LED mean...
Setting Data (SD) vs Machine Data (MD) on SINUMERIK 828D: Number Ranges, Activation Types and Access Levels
On the 828D both MD and SD live in SRAM but do completely different jobs: MD defines what this machine physically is, and getting it wrong means alarms or even a crash; SD is the o...
FANUC Parameter Write Protect (PWE): How to Unlock Parameters, SW0100, and the 3210/3211 vs 3202#4 NE9 Mix-Up
Four independent locks can stop you editing a FANUC control. This guide gives the MDI to SETTING to PWE path, explains why SW0100 is only a status message, and corrects the widespr...
FANUC SERVO GUIDE: Waveform Analysis, Vibration Suppression and Rigid Tapping
A field guide to FANUC SERVO GUIDE: what it does, which controls it supports, how to install and connect over Ethernet, and the four workflows that solve most servo problems.






















