一句话答案:CNCShare’s English section is a field-tested troubleshooting library for FANUC, SINUMERIK and HEIDENHAIN controls — covering PMC ladder logic, servo tuning, alarm diagnosis and repair — written for engineers standing in front of a machine, with what to check first and what each value means.
FANUC Troubleshooting Guides, Repair Tools and Remote Support
Welcome to the CNCShare English section — practical, field-tested guides on FANUC CNC electrical commissioning, PMC ladder programming, servo tuning, alarm diagnosis and troubleshooting.
Everything here is written for engineers who are standing in front of a machine: what to look at first, which number to read, and what a given value actually means. No theory for its own sake.
Not sure where to start? Jump to the “Which guide do I need?” section at the bottom — it maps the most common field situations to the right article in four questions.
← Browse all English articles (full list)
FANUC Troubleshooting
CNC Repair Tools
Remote Technical Support
1. PMC Ladder Programming and Project Workflow
Start here if you need to read, write, or deliver a PMC sequence program.
- FANUC PMC Ladder Diagram Beginner Tutorial — basic vs function instructions, the difference between sequential execution and relay logic, and two complete examples (tool magazine positioning + spindle coolant timer). Start with this if ladder is new to you.
- FANUC PMC Project From Scratch: The 6-Stage Flow — how to run a whole PMC project: site survey, full backup, address planning, safety-first logic, online download, staged verification. Includes the five things to hand over and the four steps people skip. This is the methodology backbone of the series.
- FANUC PMC: Edit on PC and Send Back to NC — getting the ladder onto a PC and back to the machine. Covers version matching, edit format vs memory card format, serial setup, and the critical READ = in / WRITE = out distinction.
- FANUC LADDER III: Compile, Decompile and Program Protection — why you must compile before downloading and decompile before editing, plus how password protection works and why a lost password cannot be recovered.
- FANUC PMC Troubleshooting: 5 Real Cases — spindle not starting, ATC timeout, E-stop that won’t reset, lube pump timer fault, hydraulic chuck no action. Uses a four-step signal-tracing method.
- FANUC PMC External Alarm Reverse Lookup — when the control shows an external/manufacturer alarm (1000–2999 range), how to go from the alarm number to its A address, trace the ladder, reach the I/O point, and confirm by forcing the signal. Includes the “signal present but no alarm” trap.
- FANUC Data Backup and Recovery: ALL I/O, BOOT SRAM and CF Card Sizing — the three backup routes, what actually lives in SRAM versus FROM (the ladder is in FROM, and it does not come back with an SRAM-only restore), and the CF capacity limits that matter.
- Fanuc Macro B Guide: Variable Partitions, G65/G66/G67 Calls — variable common vs local partitions, the G65/G66/G67 macro-call forms and nesting limits, with the PS alarms to watch.
- FANUC LADDER III — version selection for 0i-D/F/MF, installation without the classic failures, and the five beginner pitfalls with their fixes.
2. Diagnosis and Fault Finding
Start here when something is wrong but you are not sure what.
- FANUC Diagnosis Numbers (DGN) Quick Reference — 100+ diagnosis numbers grouped by function (000–039 execution, 200–299 servo, 300–399 position, 400–499 spindle, 500–605 overtravel and PMC), with alarm cross-reference and how to view/export them on your machine.
- FANUC No-Alarm Fault Diagnosis — the hardest class of fault: nothing on the screen, but the machine won’t move. Maps it to DGN000 (M-code not confirmed), DGN003 (in-position check) and DGN005 (axis interlock), with the interlock signal table.
3. Servo Tuning
Start here for vibration, overshoot, noise or contouring problems.
- FANUC Servo Gain 2021 / 1825 Adjustment — official starting values, the inertia-ratio conversion formula, the 5000 vs 50–80 unit confusion explained, semi-closed vs full-closed loop, and waveform-to-parameter interpretation.
- CNC Servo Vibration, Overshoot and Noise — classifies the four kinds of “shake” (high-frequency squeal, low-frequency flutter, start/stop overshoot, machining ripple) and gives the right branch for each. Also covers HRV filters and when to stop tuning and check the machine.
- FANUC Inertia Ratio: Hand Calculation, Parameter 2021 — get the load inertia ratio right before touching gain — the hand calculation, the conversion, and how the series differ.
- Fanuc Backlash Compensation 1851: Measure, Convert, Verify — measuring backlash, converting it into detector units, and checking the result instead of over-compensating.
- Fanuc Pitch Error Compensation 3620–3624: Laser Measurement to Verification — point numbering, parameter entry, and the accuracy check that has to follow.
- FANUC Servo Amplifier: Repair or Replace? — the four cost items — direct, downtime, risk and hidden — plus a decision table for swap versus repair.
- SINUMERIK Contour Error and Following Error Tuning — Kv factor, feedforward and friction compensation on 828D/840D, with the 25050/25040/25080 monitoring alarm order and a circularity test to prove the result.
- FANUC SERVO GUIDE — waveform capture at 48 kHz, FFT notch filtering, rigid tapping and HRV modes, with the backup-first safety discipline for servo tuning.
4. FANUC Alarm Code Reference (6 Parts, 0001–5559)
A complete working English reference for FANUC P/S (Program / Setting) alarm numbers, split by range so you can look up a code the moment it appears on screen. Each part lists the alarm message and the practical meaning or first action.
- Part 1 — P/S 0001–0224 — tape and format errors, G code and feed, circular interpolation, tool compensation, reference position return, program and sequence numbers, macros, rigid tapping.
- Part 2 — P/S 0230–0461 — canned and compound cycles, nano smoothing, synchronous / mixed / superimposed axis control, skip functions, tool life, real-time macros.
- Part 3 — P/S 0492–1308 — 3D interference check, Cs contour control, thread cutting, macro syntax and variables, program registration, G10 parameter input.
- Part 4 — P/S 1332–1973 — 3D handle feed, normal direction control, M code duplication, index table, program security, EGB, RS-232C, USB memory and memory card.
- Part 5 — P/S 2032–5110 — Ethernet and data server, P-CODE macros, peripheral axis control, sheet-metal and punch-press cycles, nibbling, program limits and feedrate.
- Part 6 — P/S 5130–5559 — PMC axis overlap, flexible synchronous control, tool management and interference, Cs contour control, tilted surface machining G68.2, option authentication.
5. System Alarms, Power, Other Brands & Machine Checks
Start here for board-level and power-related faults, and for non-FANUC controls.
- FANUC System Alarm 950 / 971 / 974: Meaning and Board-Level Diagnosis — these are system/PSM alarm numbers that point at a hardware or drive board, not a parameter. How to read the sub-code, isolate the suspect board, and what an external alarm (900–976) actually means.
- FANUC Battery Alarm 306 / 307: How to Replace Without Losing Zero Return — the absolute-position battery is low. The safe order to swap it, why you must keep the axis powered during the change, and how to recover the reference position if it is lost.
- FANUC MPG Handwheel Not Working? — when manual pulse generation doesn’t move the axis: signal-chain check from the handwheel encoder through the I/O to the parameter, and the common cause (HS21/HS22 selector or the feed-rate override).
- SINUMERIK 840D / 828D UAFEHL Alarm — the PLC stop alarm on Siemens controls: what UAFEHL means, why the PLC halts, and the usual triggers (I/O module, drive enable, safe-integration).
- FANUC 0i-Mate / 0i-D Alarm Quick Reference — same number, different meaning across series — including the 950/960 traps and the FSSB 5134–5198 range.
- SINUMERIK 828D Alarm 2000 / 2001: PLC Sign-of-Life Monitoring — what the sign-of-life alarm actually monitors on the 828D, and where to look first.
- Mitsubishi M80 / M70 Servo Parameters #2201–#2210 — the full servo parameter table for M80/M70 in one place.
- Mitsubishi M80 / M70 Alarm Codes: M01 / S / Y / Z / AL Families — how the M80/M70 alarm families are grouped, and which ones point at the drive rather than the program.
- SINUMERIK 828D NCK Battery Alarm 2100/2101/2102 — replace live or power down, what data is lost, and how the fan/battery module comes out.
- Heidenhain TNC Error Code List: How to Read 6-Digit Codes — the structure of 6-digit TNC errors and the high-frequency families worth memorising.
- Heidenhain Touch Probe Calibration: iTNC 530 vs TNC 640 — two generations, two systems — MP numbers on iTNC 530, Cfg on TNC 640 and later.
- Heidenhain TCH PROBE 31 / 481 Tool Length Measurement: MP vs Cfg — the two cycle formats (31.x four lines vs 481 one line of Q parameters), the three Q340 modes, Q260 clearance height with the MP6540 vs safetyDistStylus safety zone, and the 99 vs 20 individual-tooth limits.
- Fanuc G41/G42 Interference Alarm: The 2×TNR Rule — the minimum radial step rule behind most cutter-compensation interference alarms.
- Used CNC Machine Electrical Inspection Checklist — 30 Checks — for buyers: what to check before money changes hands, and the common ways faults get concealed.
- SINUMERIK 828D User Alarm Bits: DB1600 Sequential Mapping — the sequential bit-to-alarm mapping and how it differs from the 840D grouped scheme.
- SINUMERIK 828D Extended User Alarms 701000–701999: DB9913 Config — configuring DB9913 and the compatibility-mode checkbox that blocks it.
- SINUMERIK 828D Semi-Closed Loop Conversion: MD, PLC Bits, Backlash — the three layers — NC machine data, PLC interface bits and backlash compensation — that must move together.
- SinuTrain for SINUMERIK Operate: Install, Program, Simulate — install the Siemens PC simulator on Windows 10/11 and prove programs offline before the machine is tied up.
- SINUMERIK 828D PLC Programming Tool — install, connect and back up the 828D PLC program: LAD/FBD/STL editing, online monitoring, Upload Station to PG, and where to get the software legitimately.
- FANUC Servo Amplifier Replacement: Discharge, Teardown, Motor ID, Verification — the full swap procedure: power-off and discharge, teardown order, motor ID No.2020 write-back and the three post-swap checks.
- FANUC Spindle Amplifier Alarm Codes Full List: SPM/PSM Two-Digit LED 01–88 + Replace-vs-Wire Decision — the complete amplifier LED code table (01–88 plus A/b0/C0 letter codes) with a swap-board-or-chase-wiring triage; clarifies that SP9012 and SPM alarm 12 are the same fault seen from two sides.
- Will Changing the HEIDENHAIN Battery Erase Your Programs? iTNC530 / TNC640 / TNC7 — no: programs, parameters and tool tables live on the hard disk / CF. Covers the dual-storage architecture, Renata CR2450N (ID 315878-01), the 5-step live swap, what the GoldCap buys you, and the four backup media.
- 840D sl Safety Integrated Alarms 27097 / 27801 / 27810 / 27350 — SPL not started, safe operating mode vs PLC config mismatch, and F_DP communication error. Each mapped to its machine data (MD28082/28083/11602, MD13370, MD36901/37950, MD13336–13348), with a field troubleshooting order.
- How to Write Mitsubishi M80 Ladder Logic into the CNC — RAM write, ROM copy and Checksum ERROR: the GX Developer / GX Works2·3 flow, why copy-to-ROM is mandatory, and the root causes of Checksum ERROR (conversion to NOP, memory corruption, version mismatch).
- FANUC ATC Alarms 1010–1024 — Why They Are Not in the Fanuc Manual, and How to Trace Them — tool changer alarms 1010–1024 are builder-defined PMC external alarms; A-address mapping, four-step reverse trace, and a four-builder same-number-different-meaning comparison.
- SINUMERIK 828D Common Machine Data (MD) Quick Reference — the most-changed 828D MDs grouped by function (axis / spindle / referencing / soft limits), with the MD band meaning and the “MD32200 is position loop gain, not a speed limit” correction.
- FANUC Alarm 459 HI HRV Setting Error — why it fires (odd/even axis pair whose two SVMs have mismatched high-speed HRV capability), how to locate it via SVM spec / amplifier ID, and the fix (align HRV level, redo SERVO SETTING, or fit a matching SVM), with the 456/457/458/468 family separated out.
- Configure an Analog Spindle / Analog Axis on SINUMERIK 828D — MD30100 / 30110 / 30120 / 30130 / 30134 and MD30200 / 30220 / 30230 / 30240, X252 (PPU240.2) and X121 analog wiring for enable/direction, MD32250 / MD32260 scaling, plus three encoder feedback options and the NCK reset caveat.
- Heidenhain TNC “Guard Doors Are Open” Alarm — four-layer safety-chain isolation (door-switch mechanics -> safety relay -> PLC digital input -> NC door flag), the four root causes, how it gates the TS/TT probes, and the four verification tests required after any change.
- SINUMERIK 828D After a Servo-Motor / Encoder Swap — the MD34210 adjustment state machine (0 -> 1 -> 2), MD34090 reference-point offset, three-phase incremental referencing (34000 / 34010 / 34020 / 34060 / 34070 / 34080+34090 / 34100), when readjustment is mandatory, the cases NCK cannot detect, and the post-swap verification checklist.
- Export / Print FANUC Parameter Tables and Ladder Programs — three backup routes compared: the one-click full backup (0020 / 0313#0 / 0138#0, two stages, one power cycle mandatory), BOOT-screen SRAM backup (starts before the NC, unaffected by alarms) and per-item punch output, plus how to export the PMC ladder to card and write it back to F-ROM.
- Setting Data (SD) vs Machine Data (MD) on SINUMERIK 828D — the official data-area number ranges (MM display / MN general / MC channel / MA axis, with 41xxx / 42xxx / 43xxx as setting data), the four activation types (po / cf / re / so), the seven access levels, and how to debug a change that appears to do nothing.
- Fanuc Tool Change Stuck: Four Manual Recovery Methods for a Jammed ATC Arm — locate the jam among six possible points, then escalate by intervention depth: PMC force output (standard FORCE needs the PMC stopped; latching OVERRIDE covers X/Y only), direct 24V to the solenoid (20-40 ohm coil, 2-3 s, never 110/220 VAC), pressure relief with lockout, then hand-cranking the arm motor. Includes the two-way X/Y read and four post-recovery checks.
- How to Clear All Parameters on a Fanuc Control — there is no “restore factory settings” menu on a 0i-MD / 0i-MF; the real entry is the RESET + DELETE power-on combination. Explains the four different “clears”, the screen-by-screen key sequence, what SRAM wipes versus what FROM keeps, and the five post-clear checks.
- Fanuc PMC R9000 System Relays Explained — addresses from R9000 up are a system-reserved block you can read but never write. Covers constant ON/OFF (R9091.0/.1), the 200 ms / 1 s cyclic pulses (R9091.5/.6, +/-8 ms error), R9000 operation-result bits, R9002-5 division remainder, model range differences, and the two common misuses.
- How to Set Up Fanuc Tool Life Management (TM) — from the master switch to a working alarm: 8132#0 enable, 6813 max groups (mandatory on 0i-F), 6800 GS1/GS2 group x tool combinations, 6800#2 count vs time, 13203#7 count trigger, 6810 ignore number, G10 L3 group programming, and wiring F64.0 (expired) / F64.3 (pre-warning, needs 6805#4=1) into the PMC.
- How to Read a CNC Machine Electrical Schematic — from symbols and wire/sheet numbers to reading the power and control circuits, and how PMC X/Y addresses map back to real I/O points on the drawing — ending with a four-step alarm-tracing walkthrough.
- FANUC SV0381/0384/0385/0386/0387 Servo Alarms: Poor Grounding and the Linear Scale (EXT) Alarm Family — when these alarms trip on a full-closed-loop machine, the root cause is usually noise and bad grounding, not a dead scale; covers the signal chain, SDU, 4 noise paths, official shielding rules, and the 1815#1 semi-closed isolation test.
- How HEIDENHAIN TNC Tool Management Works — TOOL.T tool table vs TOOL_P.TCH pocket table, L/R offsets, tool life via TIME1/TIME2, and how the T + M6 call maps a pocket to a tool on the carousel.
- FANUC Program Transfer: RS-232, Memory Card, USB, Ethernet and DNC — the DB9-DB25 pinout, the 0020 I/O channel with the 0101/0102/0103 frame parameters, media format limits by generation, FOCAS2 port 8193 with the FTP transfer screen, and the 073/085/086/087 alarm table.
- How to Use FANUC One-Touch Setting & Servo Initialization — Parameter Setting Support (8130/1010/1020/1023) for axes, then SV SET servo init (motor ID 2020, init bit 2000#1, 1820/2084-2085/1821), then FSSB auto-setting (1902#0) and 5136 troubleshooting.
- FANUC Program Transfer Tool V18 — install, register and wire the Ethernet link: IP planning, CNC-side FOCAS2 ports 8193/8192, session setup and drag-and-drop program transfer.
- How to Use FANUC PMC Force Output (FORCE) — Entry path PMC → PMCDGN → STATUS → FORCE, forceable addresses G/R/C/A/T/E/D/Y plus X/Y latching force (OVRSET), why you must stop the PMC before forcing a ladder-used Y coil, release via OVRST/INIT then RUN, and the safety red lines.
6. How to Use These Guides
- The alarm text on your screen is always authoritative. Messages, descriptions and parameter numbers vary by FANUC series, installed options and software version. Where a guide lists a parameter number, confirm it on your machine before changing anything.
- How to Troubleshoot I/O Link & PROFIBUS Station Dropout — Reading ER97 (CH1 / 00GROUP), the I/O Link daisy-chain rule (one break takes out every higher group), three on-site checks (24 V, B-in/A-out, LED states), PROFIBUS BF blinking vs steady and the terminator/address/shielding five checks.
- Back up before you change anything. Parameters, PMC program and ladder — and verify the backup can actually be read back.
- How to Classify and Troubleshoot CNC Homing Failures — Two root classes (reference not found vs position wrong), the deceleration fork, checking grid shift 1850 and reference counter 1821, and absolute encoder APC/APZ bits, alarm 300 and battery DS0001.
- Classify before you adjust. Especially for servo problems: high-frequency squeal, low-frequency flutter, start/stop overshoot and machining ripple have opposite handling directions. Getting it backwards makes it worse the more you tune.
- Fanuc Rigid Tapping Parameters Explained — M29/G84 phase sync and P = F/S, the 5200-5294 five-block chain (enable bits, gear ratio, speed limit 5241-5244, gains 5280/4065-4068, deviation limits), DGN 452/453 reading, and a three-way SP0741 split.
- Suspect the machine before suspecting the parameters. Guide after guide in this section repeats it, because it is the most common way field time gets wasted.
- Fanuc Rigid Tapping Parameter Chart — the on-machine lookup: the five blocks of 5200-5294 at a glance, DGN 452/453/450/451 target values, the three SP0741 root causes, and alarms 200-205 in one table.
Disclaimer: These guides are a personal compilation organized from FANUC documentation and field experience. Always follow the official manual for your machine and verify by measurement on site. Operations involving safety functions must follow the relevant procedures and be performed by suitably qualified personnel.
Which guide do I need?
I’m new to FANUC PMC — where should I start?
Read FANUC PMC Ladder Diagram Beginner Tutorial first — it covers what a PMC is, the difference between sequential execution and relay logic, and the basic instruction set, with two complete worked examples. Once you can read a ladder, move to FANUC PMC Project From Scratch for the process of delivering a real project.
My machine shows an alarm number — where do I look it up?
Use the six-part FANUC Alarm Code List, split by range: Part 1 covers 0001–0224, Part 2 0230–0461, Part 3 0492–1308, Part 4 1332–1973, Part 5 2032–5110 and Part 6 5130–5559. Find your number in the left column and read the message plus the first action. If your alarm is a servo alarm in the SV range rather than a P/S number, the servo guides in section 3 are a better starting point.
My machine has no alarm but the program won’t advance — which guide?
Use FANUC No-Alarm Fault Diagnosis. It maps the three usual causes to specific diagnosis numbers: DGN000 means the system is waiting for the M-code completion signal, DGN003 means the in-position check is not passing, and DGN005 means an axis interlock is active. Keep FANUC Diagnosis Numbers Quick Reference open alongside it.
Servo vibration or overshoot — which article should I read?
Both servo guides apply, but they solve different problems. Read CNC Servo Vibration, Overshoot and Noise first to classify what you are actually seeing — high-frequency squeal, low-frequency flutter, start/stop overshoot or machining ripple — because the handling directions are opposite. Then use FANUC Servo Gain 2021 / 1825 Adjustment for the actual parameter values, the inertia-ratio formula and the adjustment sequence.
All three sections
- FANUC Troubleshooting — the guide library above: alarms, diagnosis numbers, servo, spindle, PMC and electrical faults, plus SINUMERIK, Mitsubishi and Heidenhain coverage.
- Fanuc Analog Spindle Commissioning — the four-step enable chain (8133#5, 3716#0, 3717, 3799#1) with a measurable criterion at each step, 3730/3731 voltage calibration with both formulas, the 256 kHz JA41 coder ceiling, and SP742 / SP1240 triage.
- CNC Repair Tools — what to measure and with what: instrument selection, specifications that matter, and what to leave on the shelf.
- FANUC 4th Axis Add-on Configuration — hardware and signal chain, FSSB axis-count sequence (8130/1010, 1902#1, AMP and AXIS screens), axis-definition groups with the 1020 ASCII and 1006#0 rotary traps, servo initialisation and the flexible feed-gear math, plus homing and the six PMC signals.
- Remote Technical Support — send the alarm number and machine model: diagnosis over a call, PMC analysis and technical cooperation for repair companies.
- FANUC Spindle Gear Shifting — M-type vs T-type, the core parameter set (3705/3732/3735/3741-3744/3751-3753/4056-4059), the gear-ratio math with a ZF worked example, and the PMC signals GR / CTH1A-CTH2A / SOR / *SSTP.
- FANUC Serial Spindle Alarms 749/750/751 — all three are CNC-to-amplifier serial comms alarms (not motor faults): 750 = power-on handshake fail, 749 = link dropped after ready, 751 = the amplifier's own AL-XX; the timing split, DGN 409 four bits (SPE/S1E/S2E/SHE), the amp 7-seg read (SU-01/AL-24, A/A1/A2, other AL-XX), and a hands-on procedure with the 3701#4 SP2 trap.
- Mitsubishi M80 Tool Magazine Scrambled — real vs false scrambling, the signal / parameter / mechanical split, the Setup to Tool Registration pot-by-pot fix with spindle sync, the five-step recovery and four mechanical checks, and why the M77/M74/M79 reset codes are M70-only.
- Mitsubishi M80 Magazine Scrambled Quick Chart — symptom-cause-check in one page, the four Tool Registration targets, the R10700 / R11800-R11847 / R12200 register addresses, and a 30-second symptom read.
- Mitsubishi M80 Data Backup & Restore (MPARA) — MPARA is the All Backup password, not a file format; the 7 files inside BACKUP_MANUAL, the backup/restore procedure and three rules, ALL.PRM single-file I/O with #1037, and the Z52/S52 batteries.
- HEIDENHAIN TNC Conversational Programming — Klartext for beginners: a 13-line program explained – BEGIN PGM, BLK FORM blank, TOOL CALL, L/C/CR, R0/RL/RR, DR, APPR/DEP, CYCL DEF 200 drilling, and six common mistakes.
- HEIDENHAIN TNC Block Quick Reference — the most-used Klartext blocks on one page: the 8-step layout, a block table (BEGIN/BLK FORM/TOOL CALL/L/C/CR/APPR/CYCL DEF), motion elements (R0/RL/RR, DR, I) and common M codes.
- HEIDENHAIN TNCremo / TNCcmd Transfer — TNCremo GUI vs TNCcmd command line, Ethernet LSV2 on default port 19000, same-subnet static IP and ping, the TNCremo connection steps, the TNCcmd CONNECT/MKDIR/put file, and five connection traps.
- SINUMERIK 828D External Program / DNC — three routes (copy into NC, EXTCALL from CF/USB/network, network online DNC), EXTCALL drive letters with a colon and SD42700 preset path, X127/X130 Ethernet with Access My Machine and the network manager, and why RS232 transfers but cannot DNC.
- FANUC Parameter Write Protect (PWE) — the MDI to SETTING to PWE sequence, why SW0100 is only a status message, and the correction that 3210/3211 plus 3202#4 NE9 lock O9000-O9999 programs, not parameters.
- FANUC AICC / Nano Smoothing Setup — G05.1 Q1 on and Q0 off, the PRMTUN parameter-side enable path, checking whether the option is licensed, six reasons it does nothing, the mechanical-to-smoothing tuning order, and an on/off acceptance test.
- SINUMERIK 828D Cycle Alarms 61000 / 62000 / 65xxx — why 61000/62000 are shorthand for the six-digit 06xxxx cycle-alarm range, why 065000-069999 belongs to SETAL user cycles, alarm 61000 “no tool offset active”, the five-step alarm-text to cycle-parameter order, and reset / resume rules.
- FANUC Accel/Decel and Corner Slowdown: 1620 / 1622 — 1620 for rapid traverse, 1622 for cutting feed, 1610 type bits and bell T1/T2, why small constants overshoot and large ones round corners, the accel-decel-before-AICC tuning order, and waveform plus test-cut acceptance.
- HEIDENHAIN iTNC 530 vs TNC 620 / 640 / TNC7: Differences, MP vs Cfg, and Program Migration — official generation positioning (8 vs 24 control loops), the MP-to-Cfg parameter divide, what the TNC7 brochure actually says about program and tool-table import, builder PLC and custom M-code re-adaptation, and a simulation-to-first-part acceptance checklist.
Read a troubleshooting guide, get the right instrument, or have the readings reviewed with you — the three sections are meant to be used in that order.
常见问题
What does the CNCShare English section cover?
Practical, field-tested guides for FANUC, SINUMERIK and HEIDENHAIN CNC systems: electrical commissioning, PMC ladder programming, servo tuning, alarm-code diagnosis and step-by-step troubleshooting, written for engineers working on a live machine.
How is the English section organized?
Into three areas: Troubleshooting guides (this /english hub), CNC Repair Tools (/cnc-repair-tools) and Remote Technical Support (/remote-support). Each area links to the others so a reader can move from diagnosis to tools to live help.
Do the guides apply to my exact control model?
Each guide states the control family and series it applies to. Match your machine’s model and firmware before applying any procedure, and verify with live measurement rather than assuming the steps fit.
Do these guides replace on-site safety checks?
No. They are diagnostic references, not a substitute for lockout/tagout and measured verification. Always confirm with a multimeter or diagnosis value at the terminal before changing parameters or replacing boards.