Sinumerik F-Code Cross-Reference: F300xx / F0xxx / A3xxx Mapped to 230xxx Display Numbers

A SINAMICS drive fault is called F30020 in the manual, but a 828D screen shows 230020 – one fault, two numbering systems, often troubleshot twice as if they were different problems. This page lines up F-code / 828D six-digit display number / fault meaning / first check in four columns, with the high-frequency codes broken out into linkable sections. It is a field reference, not a complete code list. Fault-value definitions differ between firmware versions – always verify each entry against the manual for the version on your machine.

Sister article: SINAMICS F codes to 828D display numbers – full Chinese cross-reference. Related: 840D sl / 828D UAFEHL alarm localization, 828D PLC sign-of-life alarm 2000/2001, 828D common machine data quick reference, 828D/840D following error and contour tuning.

1.1 How the numbering maps: manual F3xxxx vs screen 230xxx

How the four code families map

Sort by family first, then look up the individual code – it removes half the wasted diagnosis:

FamilyManual form828D/840D displayClassOwned by
Power unitF3xxxx230xxx (six digits)Fault, stopPower module / drive object
Drive objectF0xxxxsee local diagnostic screenFault, stopOne drive object (motor / encoder)
CommunicationF2xxxxsee local diagnostic screenFault, stopDRIVE-CLiQ link
WarningA3xxxx / A0xxxx6xxxxx band (version dependent)Warning, no stopDrive object / communication
广告

Table 1. What each numbering family covers; display numbers follow the system version and the local diagnostic screen

The classic trap: F3xxxx often maps to 230xxx on 828D, but it is not a simple numeric offset – individual codes and firmware versions do not always follow the pattern. Verify every F-code to 230xxx mapping against the manual for your own machine; do not copy another machine’s table. The A/F distinction tells you whether the drive stops, which decides how urgently you must react.

1.2 Power unit family F300xx, code by code

Power unit family alarm entry points
F code828D displayMeaningFirst check
F30001230001Power unit overcurrentCheck power cable to ground / between phases, motor insulation, current transformer, then the power module last
F30002230002DC link overvoltageCheck braking resistor and chopper, regenerative settings, supply voltage and DC link monitoring
F30003230003DC link undervoltageCheck supply phase loss / dip, 24 V supply, fuses and control power
F30004230004Inverter overtemperatureCheck cooling fan, heat-sink airflow, ambient temperature and load
F30005230005I2t overloadCheck load and accel/decel times, whether motor rated current matches parameters
F30011230011Main circuit phase lossCheck fuses, power cable, line reactor; a leftover star point in a star-delta setup gives the same symptom
F30020230020Configuration not supportedCheck drive-object configuration, firmware, current-loop dynamic request – fix configuration, not hardware
F30021230021Ground faultCheck power cable, motor insulation, current transformer, brake closing instant, braking resistor short (see r0949 split)
F3005023005024 V overvoltageCheck 24 V supply output, external supply feed-in and terminal voltage

Table 2. Common power-unit F codes, four-way reference (display numbers and fault values follow the local diagnostic manual)

Of these nine, F30011 and F30021 are most often misread as a bad module: for F30011 check the wiring method and any leftover star point first; for F30021 read r0949 to see which branch you are in before deciding between cable and module. Working through these two before swapping hardware avoids a lot of downtime and spare-part waste.

1.3 F30020 configuration not supported: fix configuration, not hardware

F30020 means a requested function is not supported by the current configuration – not a hardware failure. Typical triggers: an excessive current-loop dynamic request, DRIVE-CLiQ timing not permitted, firmware incompatible with the configuration, or initialization not complete.

Field order: note the full alarm number and the drive object that raised it -> look up that entry’s fault value -> decide configuration versus hardware -> isolate power before checking topology and firmware -> after changing configuration do a POWER ON. Configuration changes need a POWER ON to take effect; clearing the alarm does not mean the configuration was applied.

1.4 F30021 ground fault: r0949 decides cable versus module

F30021 has several documented causes: power cable ground fault or short, poor motor insulation, current transformer fault, the transient when the brake closes, a braking resistor short. The r0949 fault value is the fork in the road: r0949 = 0 points more to hardware DC monitoring action or a braking resistor short; r0949 > 0 relates to the total current amplitude.

The exact fault-value conventions must be checked against the manual for your version – definitions are not identical across releases. Check insulation and cabling first, evaluate the power module only after external shorts are ruled out.

1.5 F07011 motor overtemperature: three sensing paths

Three motor overheat sensing paths
F code828D displayMeaningFirst check
F07011see local diagnosticMotor overtemperatureCheck KTY84 / PT1000 sensor, PTC normally-closed contact, additional overload protection – three separate paths
F07012see local diagnosticDrive overtemperatureCheck drive cooling, fan, ambient temperature
F07013see local diagnosticDrive overcurrentCheck motor and power cable, output to ground
F07050see local diagnosticDrive parameter errorCheck drive-object parameters against firmware version
F31100 / F31110see local diagnosticEncoder / measuring system faultCheck encoder cable, DRIVE-CLiQ topology and connectors

Table 3. Common drive and encoder family F codes (display numbers follow the local diagnostic screen)

The fault value on F07011 carries real meaning (in some versions 200 is the I2t model channel and 400 is the additional overload protection trip), and the two actions are completely different – one is a thermal-model parameter and load issue, the other an external protection circuit. Read the exact fault-value definition on your own machine before acting.

1.6 A30010 sign-of-life lost: swap the cable and see if the alarm follows

A30010 (sign of life lost) is a communication-family warning: common causes are a loose or badly shielded DRIVE-CLiQ cable, a motor module fault, a 24 V dip, or a topology change without re-detection.

The one decisive test: swap a cable and see whether the alarm follows – if it follows, it is the cable or connector; if not, it is the module or topology configuration. Compared with repeated resets or swapping modules, this is the fastest move. A-class alarms do not stop the machine, but they often precede a more serious fault – do not ignore them for long.

1.7 Fault value r0949 quick reference: the configuration versus hardware fork

Reading fault value r0949
AlarmTypical r0949Points toAction
F30020low four bits 0-6Configuration / timing / firmwareChange configuration, check firmware, POWER ON
F30021= 0Hardware DC monitoring or braking resistor shortCheck braking resistor and DC circuit
F30021> 0Related to total current amplitudeCheck cable, motor insulation, ground
F07011version dependent (e.g. 200 / 400)Thermal model channel / additional overload protectionParameter-load issue versus external protection circuit
广告

Table 4. How to read fault value r0949 (exact definitions follow the manual for your version)

Remember this: the fault value decides the branch between configuration, hardware and wiring. Copying only the alarm number and ignoring the fault value throws away half the diagnostic information.

1.8 Encoder family and supplementary codes

Field-circulated SINAMICS diagnostic lists include encoder-family codes F31100 / F31101 / F31110 / F31112 / F31117 / F31130 / F31150, plus a supplementary set F07403 / F7452 / F7453 / F7491 / F7492 / F7493. These come from third-party field lists and must be checked entry by entry against the manual supplied with your machine before being used as a criterion. Note that F7452 / F7453 belong to EPOS and limit functions, a different function domain from the main drive alarms – do not read them on the same table.

The common entry point for encoder-family faults: is the DRIVE-CLiQ topology consistent with the installed hardware -> encoder cable and connectors -> reading head / encoder itself -> whether 24 V dipped at the moment of the fault.

1.9 Reset and POWER ON rules

Alarm classPOWER ON neededKey point
A-class warningUsually POWER ON to confirmAfter clearing, watch for recurrence
Configuration fault (e.g. F30020)POWER ON after changeReset is not the same as configuration applied
Hardware / wiring faultReset after root cause removedRemove the root cause before reset, never run with a latent fault

Table 5. When to reset and when to POWER ON (follow the local diagnostic manual)

Three checks before replacing any module: is the DRIVE-CLiQ topology consistent with the hardware, what firmware version is fitted, and did the 24 V dip at the moment of the fault. Rule these out before deciding to swap a module.

1.10 Sources, version and compliance note

This page only summarizes number mapping, fault-value reading direction and first checks. It does not reproduce Siemens diagnostic manual text and provides no manual mirrors or download links. Codes, display numbers and fault values come from common field diagnostic frameworks, compiled 2026-11-19. Display numbers and fault-value definitions can differ across system versions and drive objects – on site, the official diagnostic manual for the matching version and the machine’s own diagnostic screen are authoritative.

For the full troubleshooting method, see the sister article on SINAMICS F-code diagnosis (230020 on 828D) and the guide to layering 828D / 840D servo alarms 25000 / 25010 / 25201, listed in further reading at the end.

Frequently Asked Questions

How do SINAMICS F codes map to the six-digit numbers shown on SINUMERIK?

On most 828D systems F3xxxx corresponds to a 230xxx display number, but it is not a simple numeric offset – individual codes and firmware versions differ. Verify each entry against the manual for your own version; do not copy another machine’s table.

Are F30020 and 230020 the same fault?

Yes – the same fault written two ways: the manual says F30020, the 828D screen shows 230020. It is a “configuration not supported” case, so the action is to fix configuration, check firmware and do a POWER ON, not to replace the power module.

Why include fault value r0949 in an F-code table?

Because the fault value decides the diagnostic direction: it is the fork between configuration, hardware and wiring faults. For F30021, r0949 = 0 versus greater than 0 points respectively to the braking resistor / DC circuit and to external cabling / insulation. Exact definitions follow the manual for your version.

Last updated: 2026-11-19

Beyond the cross-reference: F-code troubleshooting and r0949 reading

Where to go next

Read the guide, get the right instrument, or walk the diagnosis through with someone — pick whichever you need.

© 版权声明
THE END
喜欢就支持一下吧
点赞10赞赏 分享
评论 抢沙发

请登录后发表评论

    暂无评论内容

CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
Fanuc Canned Cycles Explained: G73, G81, G82, G83, G84 to G88, Address Words, Parameters 5121/5213 and Alarm 045-CNCShare | 数控电气技术中心
FANUC 固定循环怎么用?G81 / G82 / G83 / G73 / G84 / G85 / G86 / G87 / G88 九个循环一张表选对 + Q/R/P/K 地址字 + 参数 5121/5213 + 045 报警根因-CNCShare | 数控电气技术中心
SINUMERIK Servo Tuning: p1400, p1460, p1462, p1960 and p1656 — Reading the Bode Plot to Stop Servo Humming-CNCShare | 数控电气技术中心
SINUMERIK 828D / 840D sl 电机嗡鸣、振动怎么调?驱动侧 p1400 / p1460 / p1462 / p1960 自优化 / p1656 陷波 + Bode 图判读 + NC 侧 Kv 的先后顺序-CNCShare | 数控电气技术中心
SINUMERIK Drive Faults Explained: F30020, F30021, F30011, F07011 and A30010 — the 230xxx Mapping, r0949 Fault Values and First Checks-CNCShare | 数控电气技术中心
SINAMICS F 码怎么查?828D 上的 230020 到底是 F30020 —— F30001 / F30011 / F30021 / F07011 / A30010 逐条对照 + r0949 故障值读法 + 首选检查动作-CNCShare | 数控电气技术中心
Sinumerik F-Code Cross-Reference: F300xx / F0xxx / A3xxx Mapped to 230xxx Display Numbers-CNCShare | 数控电气技术中心
SINAMICS F 码 ↔ SINUMERIK 828D / 840D sl 显示号 四向对照总表:F 码 / 230xxx 六位号 / 故障原因 / 首选检查动作(每条可链)-CNCShare | 数控电气技术中心
FANUC PMC Scan Time: Why Inputs Get Missed and Timers Fire Early-CNCShare | 数控电气技术中心
FANUC PMC 扫描周期怎么导致信号漏采、定时器提前:中文现场排查-CNCShare | 数控电气技术中心
Schematic ↔ I/O Table ↔ PMC Ladder: Three-Way Cross-Reference Fault Tracing-CNCShare | 数控电气技术中心
电气原理图 ↔ I/O 分配表 ↔ PMC 梯形图三方对照:从报警反查到端子和元件的完整路径-CNCShare | 数控电气技术中心
文章精选
专心做好一件事
打造更优雅的WordPress主题-CNCShare | 数控电气技术中心
专心做好一件事
打造更优雅的WordPress主题