SINUMERIK 828D / 840D sl vs FANUC vs Mitsubishi M80 Parameter Cross-Reference (Aligned by Function)

When you write a machine-conversion proposal, run a dual-brand service team, or evaluate spare-part substitution, what you need is "for this one function, which parameter in each control?" The three numbering systems do not map to each other: Siemens uses MD machine data numbers, FANUC uses decimal parameter numbers, Mitsubishi uses # parameters. Sorting by number range never lines up. This table aligns by function across the axis, servo, spindle, soft-limit, compensation, filtering and tuning items, with a deep-linkable anchor on every row.

Declaration (read first): the meaning, units and activation conditions of every parameter are subject to the official manual for the corresponding machine model; the same function can differ across control versions and machine-builder defaults. This table is a function cross-reference and lookup entry only — it is not a parameter manual and must not be copied as a setting-value table. The parameter numbers are just the entry points for the same function; units, signs and dimensions differ, so never transfer a value from one control to another directly.

广告

Sister article: 828D vs FANUC vs Mitsubishi Parameter Cross-Reference (Chinese); three single-brand sources: 828D Common Machine Data Quick Reference, FANUC Parameter Number Map by Range, Mitsubishi M80/M70 Servo Parameters.

29.1 Why align by function, not by number range

Three numbering systems

Table 1 Three numbering systems (different systems, no number-to-number mapping)

ControlParameter namingExampleUnit/dimension trait
SINUMERIK 828D / 840D slMDxxxxx machine data, SDxxxxx setting dataMD32200 position loop gainaxis index [0..5], per channel/axis
FANUC 0i/3x seriesdecimal parameter + bit #1825 position loop gain, 2021 inertia ratiounits vary, often in 0.01 steps
Mitsubishi M80 / M800S#xxxx parameter + SV number#2205 speed loop gain, #2238 notch frequencyhex/decimal mixed, SV and NC numbers coexist

The only correct workflow: decide what function you are adjusting (e.g. backlash), find that control’s entry in the matching column, then confirm meaning and units in that machine’s manual. Never guess a function from a number range — the three systems partition numbers on completely different logic.

29.2 Axis and motion: soft limits / backlash / acceleration / rapid speed

Axis parameters are the most-used group in a cross-reference. This table lines up the four common entries (including 840D sl).

Table 2 Axis and motion parameter cross-reference

FunctionSINUMERIK 828D/840D slFANUCMitsubishi M80Notes
Backlash compensationMD32450 BACKLASH1851 (rapid: 1852)#2011 (G00) / #2012 (G01, unit 0.5 um)Units differ: Siemens mm, Mitsubishi 0.5 um — do not copy the number
Positive soft limitMD36110 POS_LIMIT_PLUS1320 stored-travel positive boundarysoft limit per M80 manualFANUC 1320/1321 are per-axis stored travel boundaries
Negative soft limitMD36100 POS_LIMIT_MINUS1321 negative boundaryper M80 manualleave travel margin inside the hard limit
Max axis accelerationMD32300 MAX_AX_ACCEL1620 / 1622 accel/decel time constantsaccel/decel time constants per M80 manualSiemens is an acceleration value, FANUC mostly time constants — different dimensions
Rapid speedMD32000 MAX_AX_VELO1420 per-axis rapid speedrapid speed per M80 manualunits/ranges per each manual
Max cutting feedSD43200 etc. (mode dependent)1422 max cutting feedper M80 manual–

Reading note: backlash is the easiest item to “copy the wrong number” — Siemens MD32450 is usually in mm while Mitsubishi #2011/#2012 are in 0.5 um units, so the same 0.05 mm backlash is written completely differently. All soft limits must leave a safety margin inside the hard limit; verify against measurement and your manual.

29.3 Spindle: speed limits / gear shift / orientation / constant surface speed

Table 3 Spindle parameter cross-reference

FunctionSINUMERIK 828D/840D slFANUCMitsubishi M80Notes
Gear-step max/min speedMD35140 GEAR_STEP_MAX/MIN_VELO_LIMITper-gear speed params per 0i/3x manualper M80 manualmulti-gear spindles indexed by step
Spindle orientation angleorientation MD/SD per manual4077 orientation stop position (common)per M80 manualangle works with PLC/PMC logic
Constant surface speedG96 related setting dataG96 related params per manualG96 related per manuala G-code function; parameter items differ
Spindle syncspindle-sync MD (MD35xxx series)sync/rigid-tap params per manualper M80 manualvaries by model/option — entry only, no value

Discipline: spindle parameters are tightly coupled to the machine builder’s PLC/PMC logic (gear shift, orientation, sync all read the ladder) — during a conversion you cannot move parameter numbers alone; you must evaluate the PLC/PMC side together. Items not directly verifiable in a manual are listed as “per manual” with no guessed value.

29.4 Zero points and coordinate systems: G54-G59 / additional zero / offset write

Zero point coordinate entries

Table 4 Zero point and coordinate entry cross-reference

FunctionSINUMERIK 828D/840D slFANUCMitsubishi M80Notes
Workpiece zero offsetG54-G59 settable zero offsetsG54-G59 work coordinatesG54-G59 work coordinatesall three support it; UI/write method differs
Additional work coordinateadditional zero offsets per channelG54.1 Pn additional work coordinatesadditional coords per M80 manualFANUC G54.1 needs a parameter enabled
Offset writevia SET/setting data or programG10 L2/L20 write offsetswrite command per M80 manualwrite methods differ greatly

29.5 Alarm / watchdog and battery related parameters

Table 5 Alarm and monitoring entry cross-reference

FunctionSINUMERIK 828D/840D slFANUCMitsubishi M80Notes
Contour monitoring thresholdMD32210 POSCTRL_MONITOR etc.1828 moving error limit / 1829 stopping error limitper M80 manualthreshold meanings differ, per manual
In-position widthpositioning window MD1826 per-axis in-position widthper M80 manual–
Battery voltage / data retentionbattery alarm MD/PLC bitbattery alarm and absolute-position paramsper M80 manualsystem level, see brand battery articles

29.6 Lubrication / coolant / air pressure (pulse period / pressure-switch delay)

Table 6 Lubrication / coolant / air entry cross-reference

FunctionSINUMERIK 828D/840D slFANUCMitsubishi M80Notes
Lubrication pulse periodset by PLC program plus MDset by PMC ladder plus timers/data tableset by PLC programnone has a single cross-brand parameter
Pressure-switch delayPLC timerPMC timer / D data tablePLC timerfield delay per process and manual
Coolant controlPLC / M functionPMC / M functionPLC / M functionno unified parameter number

Key insight: auxiliary actions such as lubrication, coolant and air pressure are implemented in the PLC/PMC on all three controls — there is no “same-number cross-brand parameter”. Any claim of “parameter X is the lubrication period” must first identify which brand and which machine-builder PLC version.

广告

29.7 Compression and filtering: MD32400 series vs FANUC notch vs Mitsubishi #2233/#2238

Filtering and compression cross-reference

Table 7 Filter / compression / resonance-suppression cross-reference

FunctionSINUMERIK 828D/840D slFANUCMitsubishi M80Notes
Jerk filter timeMD32410 AX_JERK_TIME, MD32400 AX_JERK_ENABLEaccel/decel time constants 1620/1622, FAD relatedaccel/decel time constants per manualSiemens jerk is a separate mechanism
Vibration filter frequencyMD32412 suppression frequency, MD32414 dampingnotch filter params per HRV/servo manual#2238 SV038 FHz1 notch freq 1, #2246 2nd resonance freqMitsubishi manual explicitly: #2238 takes the AFLT frequency
Notch depth / resonance depthper MD damping termsper servo manual#2233 resonance depth (field values 0090/00A0/00B0, per manual)#2233 values subject to official manual
Program compressionCOMPCAD, BRISK (support differs 840D sl vs 828D)AI contour control G05.1 Q1 relatedhigh-precision mode G05 P10000 relatedcommand names differ; support varies by model/option

The dedicated MD32410 jerk-time tuning (including the 1/f rule) belongs to a separate SINUMERIK contour-error diagnosis topic on this site; this table gives the entry only.

29.8 Servo tuning family: Kv / position loop gain / inertia identification

Table 8 Core servo tuning parameter cross-reference

FunctionSINUMERIK 828D/840D slFANUCMitsubishi M80Notes
Position loop gain (Kv)MD32200 POSCTRL_GAIN (axis index)1825 position loop gain (unit 0.01/s)#2203/#2204 position-loop related (per manual)units differ, values are not interchangeable
Speed loop gainMD32810 speed-loop equivalent time etc.2021 inertia ratio (speed gain multiplier)#2205 speed loop gain (field ~200, per manual)FANUC 2021 is inertia ratio, not speed-gain body
Inertia ratio / identificationservo optimization incl. load-inertia ID2021 load inertia ratio#2235 inertia identification related (per manual)field values from measured identification
FeedforwardMD32620 FFW_MODE, MD326102005#1 feedforward enable, 2069 velocity FF gain2010 feedforward gain (field ~40, per manual)bit/parameter numbers differ

Correction reminder: online sources often call FANUC 2021 “speed loop gain” or 2083/2085 “position loop gain” — per official and multi-source data, 2021 is the load inertia ratio, 1825 is the position loop gain, and 2023 is the velocity feedback pulse count. Getting this wrong in a cross-reference breaks every downstream tuning decision.

29.9 Usage discipline and declaration repeated

Cross-reference usage discipline
  1. This table is a function cross-reference and lookup entry only; meaning, units and activation conditions are subject to the official manual for the corresponding model.
  2. Values are not directly convertible: units, signs and dimensions differ (backlash mm vs 0.5 um, position gain 1/s vs 0.01/s).
  3. Look up by function, never guess by number: identify the function, find the entry, confirm in the manual.
  4. PLC/PMC-coupled items (gear shift, orientation, lubrication, air pressure) cannot be moved by parameter number alone — evaluate the ladder together.
  5. Official manuals via legitimate channels: this site does not host, reproduce or link pirated manual PDFs.
  6. Further reading: 828D MD Quick Reference, FANUC Parameter Number Map, Mitsubishi M80 Servo Parameters.

Frequently Asked Questions

Which FANUC parameter corresponds to the 828D soft-limit parameter?

By function: 828D/840D sl first soft limit negative is MD36100 POS_LIMIT_MINUS, positive is MD36110 POS_LIMIT_PLUS; FANUC’s counterparts are stored-travel boundary 1320 (positive) and 1321 (negative). But the units and setting methods differ, and both need a safety margin inside the hard limit — you can say “functionally corresponding”, never “numerically equal”, subject to each manual.

How do Siemens MD and FANUC parameters map one-to-one during a conversion?

There is no number-to-number mapping, only function-to-function. Correct workflow: (1) list the functions to migrate (backlash, gain, soft limit, accel/decel…); (2) find both controls’ entries by function in this table; (3) confirm each unit/sign/activation condition in the two official manuals; (4) re-tune from measurement, never copy values. The three numbering systems partition on completely different logic, so never guess by number range.

Can this table be used as a parameter manual, and what is authoritative?

No. This table is a function cross-reference and lookup entry, not a parameter manual, and it does not give a single “correct setting value”. Each parameter’s meaning, unit, range and activation condition are subject to the official manual for the corresponding model; the same function can differ across versions and machine-builder defaults. Verify against your machine’s manual and measurement before any field change, and dry-run the first article.

Last updated: 2026-11-20

Where to go next

Read the guide, get the right instrument, or walk the diagnosis through with someone — pick whichever you need.

© 版权声明
THE END
喜欢就支持一下吧
点赞8赞赏 分享
评论 抢沙发

请登录后发表评论

    暂无评论内容

CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
SINUMERIK 828D / 840D sl vs FANUC vs Mitsubishi M80 Parameter Cross-Reference (Aligned by Function)-CNCShare | 数控电气技术中心
828D / 840D sl ↔ FANUC ↔ 三菱 M80 常用参数三方对照总表(按功能对齐,不按号段对齐)-CNCShare | 数控电气技术中心
HEIDENHAIN TNC Fixed Cycle Parameter Reference: Cycle 200/203/230/251/252/4xx Q Parameters and FANUC G-Cycle Migration-CNCShare | 数控电气技术中心
海德汉 TNC 固定循环参数速查表:Cycle 200/203/230/251/252/256/257/4xx/48x 逐个 Q 参数含义 + 与 FANUC G 循环迁移-CNCShare | 数控电气技术中心
机床为什么要预热?热变形与首件精度漂移:三处热源 + 20 分钟预热协议 + 主轴油温与环境温度设定 + 热伸长诊断方法-CNCShare | 数控电气技术中心
Replacing a FANUC Servo Motor: Parameters 2020, 2022 and 2021, Re-measuring Inertia and Re-verifying Compensation-CNCShare | 数控电气技术中心
FANUC 换伺服电机后参数怎么回写?2020 / 2022 / 2021 + 惯量比重测 + 编码器方向与对位 + 三步验收-CNCShare | 数控电气技术中心
SINUMERIK Servo Alarms 25000, 25010 and 25201: Which Layer to Troubleshoot First-CNCShare | 数控电气技术中心
828D / 840D sl 伺服报警 25000 / 25010 / 25201 怎么分层?先看 NC 报警还是 F 码-CNCShare | 数控电气技术中心
Mitsubishi MT Works2 / MR Configurator2: Official Download Path, Modules and Servo Parameters-CNCShare | 数控电气技术中心
三菱 MT Works2 / MR Configurator2 哪里下载?伺服调参上位机三大模块、怎么连 MR-J4/J5、能改哪些参数与三大下载坑-CNCShare | 数控电气技术中心
SINUMERIK 828D Tool Management NC-PLC Interface Explained: DB4300, Three Tables and the Drum-Magazine Wrong-Tool Case-CNCShare | 数控电气技术中心
文章精选
专心做好一件事
打造更优雅的WordPress主题-CNCShare | 数控电气技术中心
专心做好一件事
打造更优雅的WordPress主题