FANUC 固定循环怎么用?G81 / G82 / G83 / G73 / G84 / G85 / G86 / G87 / G88 九个循环一张表选对 + Q/R/P/K 地址字 + 参数 5121/5213 + 045 报警根因
固定循环是 FANUC 编程里一行代码干一串动作的功能,也是新手最容易出事的地方。本篇讲清三个模态 G90/G91、G98/G99、G80 的区别,九个循环 G81-G88 的选用,Q/R/P/K 地址字写法,G73 与 G83 的...
Fanuc Rigid Tapping Parameter Quick Reference: 5200–5294, SP0741 and DGN 452/453
A copy-straight-to-the-machine Fanuc rigid tapping reference: 5200-5294 grouped into five blocks (enable bits, gear ratio, speed limit 5241-5244, gains and time constants, deviatio...
FANUC 刚性攻丝参数速查表:5200–5294 区段逐条说明 + SP0741 报警码 + 诊断号 452/453 含义
可直接对着机床抄的 FANUC 刚性攻丝参数速查表:5200–5294 按五段归类(开关位 / 齿轮比 / 转速上限 5241–5244 / 增益与时间常数 / 偏差极限),逐条给出含义与常用设定;附诊断号 452/453/45...
SINUMERIK 828D/840D Following Error and Contour Error Tuning: 25050 Alarms, Kv Factor, Feedforward and the Circularity Test
What to do when 25050 contour monitoring alarms? Following official Siemens wording, this article covers the tuning order for following error and contour error on SINUMERIK 828D/84...
SINUMERIK 828D/840D 轮廓误差与跟随误差调参:25050 报警、Kv 因子、前馈、摩擦补偿与圆度测试(附参数速查表)
25050 轮廓监控报警怎么调?本文按西门子官方口径讲透 SINUMERIK 828D/840D 跟随误差与轮廓误差的调参顺序:三个监控报警的阶段区别、Kv 因子 MD32200 与跟随误差的定量关系、前馈 MD32620 系列...
SINUMERIK 828D / 840D sl 电机嗡鸣、振动怎么调?驱动侧 p1400 / p1460 / p1462 / p1960 自优化 / p1656 陷波 + Bode 图判读 + NC 侧 Kv 的先后顺序
电机嗡鸣、尖叫、走圆不圆,先分清是速度环、机械共振、NC 侧 Kv 还是机械问题。本页讲清驱动侧 p1400/p1460/p1462/p1960/p1656 调参:先 p1960 自优化、再 p1460 降 10-20% 与 p1462 升 20-50%...
SINUMERIK Servo Tuning: p1400, p1460, p1462, p1960 and p1656 — Reading the Bode Plot to Stop Servo Humming
Motor humming, squealing at one frequency, or circles that are not round - sort which layer first: speed loop, mechanical resonance, NC-side Kv or mechanics. This guide covers driv...
SINUMERIK 828D Alarm 2000/2001: PLC Sign-of-Life Monitoring, MD10100/MD10120 and the Field Fix
Alarm 2000 means the NCK lost the PLC heartbeat. How MD10100/MD10120 govern it, why an empty ISTACK means a loop instead of no fault, and the correct reset sequence.
SINUMERIK 840D/828D UAFEHL Alarm: What It Means, Why the PLC Stops, and How to Localize It via DB2
UAFEHL is not a specific fault — it is the SINUMERIK flag for 'a user alarm triggered the PLC stop.' Six root-cause families, a 5-step localization procedure, SF/STOP/RUN LED mean...
数控 24V / 5V 控制电源故障怎么查?SV0434 与 230041 官方口径 + PS0003 编号冲突 + 空载负载分离法
简报把 PS0003 / SV0434 / 230041 写成三品牌同源现象,又把经验电压表当成官方判据。核实后:PS0003 存在两套互相冲突的解释,SV0434 与 230041 的检测位置和阈值完全不同。本页把官方口径与经...