最新发布第34页
排序
FANUC No-Alarm Fault Diagnosis: How to Use DGN000, DGN003, DGN005
FANUC no-alarm fault diagnosis: map hidden faults to specific diagnosis numbers. DGN000 = M-code not confirmed, DGN003 = in-position check stuck, DGN005 = axis interlock. Includes ...
三菱 M80/M70 报警代码怎么读?M01/S/Y/Z/AL 五系族谱 + 4 位细节号(0032/0050/0052)判定与复位等级
三菱 M80/M70 报警按 M01/S/Y/Z/AL 五族划分,4 位细节号才是真正的故障身份证:S01 0032 过流要断电重启、S03 0050 过载按复位键、Z70 丢绝对位置必须回零、换电池必须通电时换。一张复位等级...
SinuTrain for SINUMERIK Operate: Install, Program and Simulate on a PC
How to install and use SinuTrain for SINUMERIK Operate on a PC: what the Siemens simulation software does, which control generations it matches, the Windows 10/11 install steps, an...
海德汉 TNC「防护门未关 / 门未关」报警怎么查:安全链四层定位 + 门开关门锁排查 + 改动后四项验证
海德汉 TNC 报「防护门未关 / DOOR OPEN / GUARD NOT CLOSED」,本质不是 NC 软件故障,而是 PLC 把「门关闭条件」判成 false。本文按安全链四层(门开关机械 → 安全继电器 → PLC 数字量输入 ...
FANUC 刚性攻丝参数速查表:5200–5294 区段逐条说明 + SP0741 报警码 + 诊断号 452/453 含义
可直接对着机床抄的 FANUC 刚性攻丝参数速查表:5200–5294 按五段归类(开关位 / 齿轮比 / 转速上限 5241–5244 / 增益与时间常数 / 偏差极限),逐条给出含义与常用设定;附诊断号 452/453/45...
FANUC Acceleration/Deceleration and Corner Slowdown: 1620 Rapid, 1622 Cutting, and the Trade-offs
Parameter 1620 governs rapid-traverse accel/decel and 1622 governs cutting-feed accel/decel, both in msec; 1610 selects exponential, linear or bell-shaped and 1621 sets bell T2. Th...
SINUMERIK 840D sl 诊断手册官方入口 + 报警章节导航:哪一族报警翻第几章
官方中文诊断手册约 1370 页,难点不是下载而是按报警号翻到对的那一章。给出官方文档检索号、两版章节页码对照、版本对齐方法与三种查法,不转载手册正文。
FANUC 0i-F / 0i-F Plus 功能选项对照与「我这台机器到底装了什么」怎么查:规格表图例、选件族与代号纠错
手册里有 AI 轮廓控制,为什么机床上用不了?操作手册描述的是全部可选功能。本页按官方 0i-F Plus 规格表讲清「书里有不等于机器上有」、符号图例、三种查证路径,并纠正几处选件代号误传。
FANUC 16i / 18i / 21i / 30i / 31i Identification: Model Reading, Axis Counts and Spare-Part Selection
A control in the shop says only '18i' on the panel - which generation, how many axes, and can spares be swapped? Official B-63002EN / B-63522EN axis totals include loader axes and ...
FANUC M98 / M99 Subprogram Calls: P Numbers, Nesting Limits and How to Troubleshoot Alarms 076 / 077 / 078
FANUC M98/M99 subprogram calls explained: four P-number formats, L repeat counts, the boundary between NC M98/M99 and PMC SUB, three uses of M99, and the conflicting nesting limits...