最新发布第29页
排序
三菱 M80 PLC 编程软件用哪个?GX Works3 / GX Developer 官方下载路径 + 版本对应表 + 安装与连机常见坑
先分清「CNC 内置 PLC」和「外置 MELSEC PLC」,再选软件。三菱官方 M800/M80《PLC 开发说明书》(IB-1501270)写明的用户 PLC 开发环境是 MELSOFT 的 GX Developer;GX Works3 官网标明对应 ME...
海德汉 TNC「防护门未关 / 门未关」报警怎么查:安全链四层定位 + 门开关门锁排查 + 改动后四项验证
海德汉 TNC 报「防护门未关 / DOOR OPEN / GUARD NOT CLOSED」,本质不是 NC 软件故障,而是 PLC 把「门关闭条件」判成 false。本文按安全链四层(门开关机械 → 安全继电器 → PLC 数字量输入 ...
How to Clear All Parameters on a Fanuc Control: RESET + DELETE Power-On Sequence Explained (and Why “Restore Factory Settings” Does Not Exist)
A good half of the 'Fanuc restore factory settings' tutorials are wrong: there is no such menu on a 0i-MD / 0i-MF. The real entry is a hardware key combo - power down, hold RESET +...
FANUC 主轴齿轮换挡参数全解:3705/3732/3735/3741-3744/3751-3753/4056-4059 + PMC 信号
主轴齿轮换挡(高低档)错得最多的是钳速参数名搞混(标准里没有 3734,最低钳速 3735、最高 3736)、3741-3744 与各档传动比算反、以及 PMC 侧 CTH1A/CTH2A 与 GR 信号没对应。本文按换挡方式...
SINUMERIK 828D Semi-Closed Loop Conversion: MD Parameters, PLC Bits and Gap Compensation
A complete SINUMERIK 828D semi-closed loop conversion guide for masking a faulty linear scale: the three layers that must move together — NC machine data (MD30200 number of measur...
加工尺寸忽大忽小怎么查?四条线分离法:机械线 / 检测反馈线 / 工艺刀具线 / 数据基准线,一次把波动源分开
尺寸忽大忽小别再靠反复调刀补硬压 —— 刀补只修稳定的系统偏差,修不了随机漂移。用四条线分离法先判断「变化跟着什么走」:随件数走是刀具磨损,随时间走是热变形,随位置走是丝杠/螺距,随...
Heidenhain TNC Error Code List: How to Read 6-Digit Codes + High-Frequency Faults by Family
The Heidenhain TNC error code reference: how to read the six-digit format (three-digit family + four hexadecimal digits), the full family map from 120 to 330 with the NC versus mac...
FANUC Main Board Spare Numbers: A16B / A17B / A20B Board Families and 5 Things to Check Before Swapping
Circulated tables like 'A20B-8100-0135 = 0i-A, -0450 = 0i-B, -0660 = 0i-C' come from different spare vendors who conflict with each other. Labeled as circulated field lists to veri...
Fanuc Threading G32 / G92 / G76: Fixing Pitch Errors and Spindle Sync Problems
Thread pitch errors are rarely fixed by tweaking a tool offset. The real cause is a broken sync chain between the spindle one-rotation signal and Z-axis feed per revolution. Covers...
Schematic ↔ I/O Table ↔ PMC Ladder: Three-Way Cross-Reference Fault Tracing
The faults that eat the most time are when the schematic, I/O table and ladder disagree. This guide maps all three documents, gives a full trace from alarm classification through A...