最新发布第31页
排序
HEIDENHAIN TNC Generation Cross-Reference: MP vs Cfg, Model Differences and Cycle Compatibility
One-page lookup for iTNC 530 / TNC 620 / TNC 640 / TNC7: positioning, control loops, NC software numbers, MP vs Cfg parameter systems, and the MP-to-Cfg mappings HEIDENHAIN officia...
828D 全闭环改半闭环怎么改?屏蔽光栅尺的 MD 参数 + PLC 位 + 间隙补偿三件套
SINUMERIK 828D 全闭环改半闭环完整教程:光栅尺故障应急屏蔽与永久改半闭环的三层改法——NC 机床数据(MD30200 测量系统数量、MD30230 输入分配把电机编码器排到第一路、MD31000/31010/31020/...
How to Classify and Troubleshoot CNC Homing Failures: Reference Not Found vs Wrong Reference Position + Decel Dog / One-Turn Signal + Grid Shift 1850 / Reference Counter 1821 + Absolute Encoder Battery
Stop swapping parts to see what sticks. Split homing failures into two classes: reference not found, and reference position wrong. In the first class, watch whether the axis decele...
海德汉 TNC 错误码对照表:6 位码怎么读 + 120/125/130/140/230 各族高频码逐条解
海德汉 TNC 错误码中文对照:六位码制(三位族号+四位十六进制序号)读法、120/125/130/140/145/160/1A0/201/230/231/280/320 全族谱与 NC 侧/机床厂侧分界、120-001E/001F/130-00A7/160-008B/2...
SINUMERIK 828D G290 vs G291: DIN and ISO Mode Side by Side
Siemens' own manual says G290 activates the Siemens NC programming language and G291 activates the ISO dialect. Each must stand alone in an NC block and the two languages cannot be...
机床精度检验怎么做?球杆仪 ISO 230-4 与激光 ISO 230-2 判据对照
球杆仪做的是圆测试(ISO 230-4),激光干涉仪做的是定位精度与重复定位(ISO 230-2 / GB-T 17421.2),两者不是一套判据。本文给出标准分工、球杆仪六步作业、官方七类误差诊断项与验收结论三...
SINUMERIK 840D/828D UAFEHL Alarm: What It Means, Why the PLC Stops, and How to Localize It via DB2
UAFEHL is not a specific fault — it is the SINUMERIK flag for 'a user alarm triggered the PLC stop.' Six root-cause families, a 5-step localization procedure, SF/STOP/RUN LED mean...
SINUMERIK Servo Alarms 25000, 25010 and 25201: Which Layer to Troubleshoot First
SINUMERIK three-code triage: 25000/25010 are NCK measuring-system alarms, while 25201 is the NC relaying a SINAMICS drive fault whose real cause is a drive-side F code. Includes a ...
FANUC Matrix Keypad Panel Replacement: Remapping PMC Ladder Logic and Resolving R-Address Conflicts
FANUC Matrix Keypad Panel Replacement: Remapping PMC Ladder Logic and Resolving R-Address Conflicts Field notes by 共享屋 (Gongxiangwu) — a real panel-swap job, compiled from wech...