最新发布第14页
排序
FANUC 外围报警(1000/2000 段)查不到原因?A 地址→梯形图→I/O 点 四步反查法
FANUC 外围报警(1000/2000 段)是机床厂用 PMC 的 A 地址做的自定义报警。本文给出四步反查法:PMC 信号状态找 A 位 → 梯形图 W-搜索线圈逆推触点 → X 点按 I/O Link 分配反查端子排 → 强制...
FANUC 参数改不了/写不进去怎么解除?PWE 参数写入开关 + SW0100 + 3210/3211 与 3202#4 NE9 混淆纠正
参数写不进去,先分清是 PWE 没开、程序编辑被保护、9000 号程序密码锁,还是新机的 8 级保护。本文给 MDI 到 SETTING 开 PWE 的完整路径,说明 SW0100 只是状态提示,并纠正把 3210/3211、3202...
FANUC 参数不见了怎么查?四种隐藏机制:选件授权 / 轴数 gating / 版本差异 / 写入权限
手册里有的参数本机翻不到,多数不是丢了。本页分开讲选件授权与可见性分离、轴数与硬件配置过滤、机型版本差异、写入权限与显示过滤,并给出现场核对五步与三类禁止试探。
FANUC PMC编程核心:深度解析顺序程序的8大数据构成
本文详细拆解FANUC数控系统PMC顺序程序的8大核心数据模块。从梯形图逻辑到I/O配置,从符号注释到系统参数,助您掌握PMC编程与调试的底层逻辑,提升机床维护效率。
Fanuc Servo Resonance and Notch Filter Setup: Finding the Frequency with Servo Guide
A squealing servo is not fixed by just lowering the gain. Based on the official FANUC servo tuning manual and the HRV filter notice: separating resonance from mechanical impact, re...
Spindle Runout: Four-Layer Diagnosis, the Two-Point Test Arbor Split and Taper Contact Pattern Checking
Runout guides publish a single universal tolerance and diagnose every far-point reading as a bearing preload problem. The two-point reading only gives a direction, and published so...
FANUC Parameter Write Protect (PWE): How to Unlock Parameters, SW0100, and the 3210/3211 vs 3202#4 NE9 Mix-Up
Four independent locks can stop you editing a FANUC control. This guide gives the MDI to SETTING to PWE path, explains why SW0100 is only a status message, and corrects the widespr...
Fanuc PMC Alarm Codes Explained: How to Read, Search and Clear a PMC Fault
How to read, search and clear Fanuc PMC alarm codes without losing your ladder.
FANUC 参数表和梯形图怎么导出/打印:一键全备份、BOOT SRAM 备份、单项穿孔输出与 PMC 梯形图存卡
FANUC 备份分三条路:0i-F / 0i-F Plus 的一键全备份必须走两段并断电重启一次;BOOT 画面下的 SRAM 备份先于 NC 启动、不受报警影响、可整块恢复;单项数据走各自画面的 PUNCH→EXEC,每次只输...
Five Peripheral Alarm Clusters on CNC Machines: Coolant, Lubrication, Chip Conveyor, Air and Hydraulics – From English Alarm Text to PMC Feedback to Action
Coolant, lubrication, chip conveyor, pneumatic and hydraulic alarms are usually written by the machine tool builder in the PMC/PLC, not by FANUC or Siemens. A cross-system matrix o...