Boundary first: these machines often have no manual online. This article gives verified multi-source meanings plus field check order, not a manual translation, not a pirated PDF, and no spare-part sales links. Alarm text, full A06B part numbers and parameter numbers must come from your nameplate and the manual shipped with the machine. For model identification method see 16i / 18i / 21i / 30i / 31i identification; for same-number-different-board issues on later controls see 0i-B / 0i-C legacy alarms.
44.1 Three checks to separate Alpha from Alpha i
Do not infer from “it says 16”. 16A/16B/16C and 16i/18i are two product lines:
| Check | Alpha non-i legacy | Alpha i / i-series |
|---|---|---|
| Panel model | 16A/16B/16C, 18A/18B/18C, 21 (non-i) | 16i/18i/21i/30i/31i/32i |
| Amplifier and nameplate | α SVM/SPM/PSM, full A06B number | αi SVMi/SPMi/PSMi, different prefix family |
| Axis communication | legacy serial cable | FSSB optical serial bus |
The same digit on an amplifier display means different things on different modules. And “α” versus “αi” is one letter but may mean a completely incompatible interface. Photograph three things: the system ID screen, the whole amplifier row with nameplates, and the servo/spindle motor nameplates. Copy the full part number including the # suffix – suffixes can mark voltage, firmware or certification versions.

44.2 Common alarms and the first check
This is a first-action list, not a complete code table. Alarm text changes with series and servo software version: read the full screen text before using the table.
| Alarm | Common meaning (verified across sources) | First check |
|---|---|---|
| SV401 | Servo not ready / VRDY OFF, amplifier is not in READY | Check E-stop chain, MCC contactor, control power, PSM supply; do not replace an axis card first |
| SV414 | Digital servo error too large, axis not following command | Check mechanical load and binding, encoder feedback, amplifier LED subcode; do not raise the error limit |
| SV416 | Pulse coder / feedback signal fault (open cable, oxidized plug, invalid signal) | Check encoder cable and connector first, then feedback power, then the motor |
| SP700 | Spindle overheat | Check spindle cooling, thermal sensor circuit, SPM ventilation and cabinet fans; a sensor fault can fake an overheat |
| SP749 | Serial link dropped after READY, often S-SPINDLE LSI ERROR | Check serial cable/fiber ends and amplifier supply, read DGN 409; full power-off restart, not just RESET |
| OT500 / OT501 | Positive / negative hardware overtravel | Check limit switch, mechanical stop and wiring; do not change overtravel parameters to hide it |
One high-frequency correction: SP749 is not a “spindle position coder alarm”. Public sources disagree (position coder / S-SPINDLE LSI ERROR / spindle overspeed). The site’s dedicated guide splits them by timing: 750 = power-on handshake failed, 749 = link came up then dropped during the run, 751 = the amplifier’s own AL-XX relayed by the CNC. See serial spindle 749/750/751 diagnosis. Get this order wrong and you will replace a good encoder while a loose serial cable stays loose.

44.3 The amplifier display is the second scene
The SV/SP number on the CNC screen is the result. The amplifier’s own STATUS display is the original information. A typical row runs left to right PSM (supply) -> SPM (spindle) -> SVM (axes), each with an independent display.
The same character means different things on different modules: digits on a PSM usually concern supply, DC link or fans; on an SVM they concern the axis power stage, control voltage or overcurrent; an SPM shows spindle-side state. Identify the module you are reading before you look up any code – otherwise the lookup is meaningless.
Two details matter:
- A trailing decimal point can separate a warning from an alarm on some modules. Do not record only the digit.
- Some legacy screens do not show a subcode. The amplifier LED is what separates SV414 into overcurrent, overheat, DC-link undervoltage or position-detection error.
For power-off/discharge and teardown order see servo amplifier replacement. Confirm capacitors have discharged before opening the cabinet.
44.4 Alpha feedback cables are not i-series cables
Legacy Alpha servo motors typically use a pulse coder. Its cable, pinout and shielding do not match an αi serial encoder. Looking similar is not interchangeable: a wrong cable can raise SV416 or trip overcurrent at power-on.
Check the feedback chain in this order:
- Inspect connectors for oxidation, water ingress or coolant soaking; rear seals on old machines fail often.
- Verify shield grounding is single-point; double-ended grounding invites common-mode noise. Look for cable pinch points at doors and cable carriers.
- Measure encoder supply voltage. A sagging supply looks like an intermittent encoder fault.
- For absolute encoders, confirm battery status. Low battery and a cable fault can both appear as feedback alarms.
- Only after all of the above, suspect the encoder or motor itself.
Motor swaps involve encoder resolution and motor ID matching; see parameter write-back after a servo motor swap.
44.5 Obsolete spares: evaluate before you buy
Alpha amplifiers and their motors are out of production. What is available comes from pulled units, refurbished stock or third-party exchanges. This is not “any board with the same outline will do”. Check every line:
| Item | Why it matters |
|---|---|
Full A06B number including # suffix | The suffix can mark voltage, firmware or certification; a partial number gets the wrong unit |
| Axis count and module type | Single/dual-axis SVM, SPM and PSM are not interchangeable |
| Encoder type | α pulse coder and αi serial encoder are not compatible; changing feedback often changes wiring too |
| Voltage and power rating | Wrong class gives overcurrent or DC-link alarms |
| Interface | Legacy serial cable versus FSSB fiber cannot be swapped directly; a cross-generation move can touch the main board |
| Parameters and motor ID | A replacement board still needs the original parameters and motor code written back |
For board-number reading see A16B / A17B / A20B board families. This site provides no spare-part sales links and does not recommend “new old stock” from unverified sellers – relabelled refurbished units are common in this market.

44.6 Three jobs after an amplifier swap
A working board is not a repaired machine. All three jobs are mandatory:
- Restore parameters. Write back the axis and servo parameters from the pre-swap backup. With no backup, compare against an identical machine or obtain the original configuration from the machine builder or FANUC service. Never copy generic parameters from the internet.
- Write the motor ID. The FANUC servo motor code (commonly around No.2020 – verify for your series) must match the physical motor. A wrong code gives parameter errors or abnormal output.
- Re-reference the machine. After an absolute encoder is replaced or loses position data, the reference point must be re-established per the machine procedure. Verify the mechanical dog and limit switch before doing so.
Teardown order and the three verification steps are in servo amplifier replacement and servo motor parameter write-back.

44.7 16A/16B versus 18A/18B: do not guess from the letter
A/B/C are generations within a product line; 16 and 18 are different positioning families. The same alarm number can carry different text across generations, and hardware interfaces and parameter blocks change too. Only three things are certain in the field: the system ID screen, the full amplifier nameplate number, and the manual matching that hardware. There is no such thing as one manual covering both 16B and 18B – configuration and options differ.
What is reliable: non-i legacy machines use Alpha drives; i-series moved to Alpha i and FSSB. Cross-generation replacement is not a board swap – it changes interface, feedback and parameter system together.
44.8 Two traps in motor replacement
- Inertia ratio. If motor inertia does not suit the load, you get oscillation, large following error and repeat SV414 alarms. Rated kilowatts alone are not enough.
- Encoder resolution. A different resolution changes pulses per revolution and the feedback scale. At best positioning drifts, at worst a feedback alarm appears immediately. Different motor models require parameter changes and recalibration.
Both belong to the same rule as 44.6: once hardware changes, parameters must change with it.
44.9 What to prepare before a service call
Legacy machines usually lack documentation. Before calling a technician or a parts supplier, gather:
- Photo of the system ID screen (full 16B/18B identification).
- Photos of every nameplate in the amplifier row – PSM, SPM and SVM – including
#suffixes. - Photos of servo and spindle motor nameplates.
- Photo of the CNC alarm screen with full text, not just the number.
- Photo or short video of the amplifier display, including any decimal point.
- Diagnostic page readings, especially DGN 409 bits for serial spindle issues.
- Existing parameter backup and I/O list; say plainly if there is no backup.
- Alarm timing: at power-on, spindle start, axis move, or intermittent during machining.
With all eight, remote diagnosis becomes far more accurate. Miss several and you are paying for a second visit.
44.10 Scope
This page provides no manual PDFs, no cracked material, no obsolete-part sales links, and does not treat a third-party alarm list as a complete code table. Legacy documentation is scarce, which is exactly why you need hard evidence: nameplates, full screen text and the amplifier’s own display – not a forum sentence claiming “16B means this alarm”. Parameter numbers and code tables must come from the manual for your machine.
Frequently Asked Questions
Can 16B and 18B share one manual?
No. A/B/C are generations and 16 versus 18 are different product families; hardware configuration, options and parameter blocks all differ. Alarm text also changes with software version. The reliable route is three checks: system ID screen, full amplifier nameplate number, and the manual matching that hardware. Using an i-series 16i/30i manual on an Alpha-based 16B applies the wrong generation of the system.
Alpha servo amplifiers are obsolete. Where can I get a usable replacement?
Realistic sources are pulled units, refurbished stock and third-party exchanges; original new units are no longer produced. Evaluate any candidate against: full A06B number with # suffix, axis count and module type, encoder type, voltage and power rating, interface (legacy serial versus FSSB), and whether parameters and motor ID can be written back. This site provides no sales links and does not recommend “new old stock” from unverified sellers.
Why must I re-reference the machine and restore parameters after a servo amplifier swap?
The amplifier is only the execution unit. Axis parameters, motor code and position data live in the control or encoder. Without a parameter write-back you get motor-code mismatch and wrong gains or error limits. After an absolute encoder is replaced or power is lost, the original position reference is gone and the reference point is no longer trustworthy. So three jobs are mandatory: restore parameters, write the correct motor ID, and re-reference per the machine procedure. A machine that moves is not automatically a machine ready for production.
Last updated: 2026-11-25
Where to go next
- FANUC Troubleshooting — the full guide library: alarms, diagnosis numbers, servo, spindle, PMC and electrical faults, organised by symptom.
- CNC Repair Tools — which instrument measures what: multimeters, clamp meters, insulation testers and oscilloscopes, with the specification that actually matters.
- Remote Technical Support — have the readings reviewed with you: alarm reverse lookup, PMC ladder analysis and servo tuning advice by call. Repair companies and integrators welcome.
- Buying & Ownership Decisions — refurbished vs new, used-machine checks, software licensing and manuals: spend with the field facts in hand.
Read the guide, get the right instrument, or walk the diagnosis through with someone — pick whichever you need.
The original Chinese version — same procedure, with the full field notes.












































暂无评论内容