Read the red line first: the D/R addresses and alarm numbers in published examples (D2000, D1070, D2148, R9000.1, OPM170, etc.) are addresses the authors allocated in their own ladder programs – they are not fixed Fanuc addresses. Copying them will fail. What is genuinely portable is the method, function code 153, parameter 4127 and the load formula; those agree across sources.
42.1 Three failure types have different load signatures
| Failure | Load signature | Detection direction |
|---|---|---|
| Wear / chipping | load rises progressively away from baseline | upper-limit factor |
| Complete break (missing tool) | load falls to roughly air-cut level | fixed lower limit |
| Partial break | air-cut before engagement, then an unstable spike | peak plus variation, multiple samples |
So the threshold must be two-sided: an upper limit alone misses the most common case, where the tool breaks and the load collapses. Sources stress that the air-cut load after breakage is not zero – it is the percentage corresponding to idle motor current. The trip point must sit between the maximum air-cut load and the minimum normal cutting load; if those bands overlap, the method cannot decide reliably.

42.2 Why spindle load: no hardware, fast refresh, already in the control
- Zero hardware cost: the load data is already in the CNC; the PMC just reads it.
- Fast refresh: load tracks cutting force, sampled at second-level or faster – closer to real conditions than time-based tool changes.
- Complements tool-life management: TM counts parts/time and changes on schedule but cannot know a tool broke mid-cycle; load detection fills that gap – see Fanuc tool life management (TM).
Caveat: on low-load operations (tapping, small-diameter finishing) the air-cut and cutting bands can be only a few percentage points apart, near the meter’s resolution. There, use a tool setter or external power monitor instead of forcing this method.
42.3 The core: PMC window function SUB51 WINDR, function code 153
Fanuc PMC reads/writes CNC data through the “window function”: read with SUB51 WINDR, write with WINDW. For spindle load, the control-data block contains:
| Control field | Value | Note |
|---|---|---|
| Function code | 153 | read spindle-motor load (consistent across sources) |
| Data number N | 0 | first spindle |
| Data attribute | 0 | example value |
| Data length | 2 bytes | unsigned binary |
| Destination | e.g. R2010 or R1212-R1213 | custom, not fixed |
The slow window function needs more than two scan cycles; its enable must be turned off before the next read, otherwise you read stale values. The fast variant completes in one scan.
Load formula (consistent across sources):
Load(%) = (L / 32767) x lambda
where L is the 2-byte raw value and lambda is parameter 4127 (the spindle load meter’s full-scale display value, machine-specific). A published example with lambda=143 scales the result by 100 for the host PC and reads 301, giving a real load of 3.01%. Use your own machine’s parameter 4127, not someone else’s 143.

42.4 Build the baseline: D data table and sampling
The idea is to teach the machine what “normal” looks like, then let it judge abnormalities:
- A panel toggle sets preset / monitor mode.
- Sample about once per second after spindle speed is reached – only inside a window where the cutter is actually engaged, not during acceleration, rapid traverse or air moves.
- Repeat sampling over many parts to cover material variation and early wear; one sample as a baseline produces many false alarms.
- Store samples in a D data table indexed by tool number. Table capacity, start address and table-internal number are planned in your own ladder; one example uses D0006=24 for capacity, D2000 as start address and index 0-23 for tools 1-24.
Consult your PMC programming manual for the data-table concept, byte structure and the ladder instruction numbers (XMOVB, COMP) used on your control series – instruction numbers differ between Fanuc PMC generations, so do not copy them from another machine.
42.5 Compare and update: COMP + XMOVB, do not invert the logic
- COMP compares the current sample with the stored baseline and drives an internal relay (examples use an R9000.x address; yours will differ).
- XMOVB moves data between the D table and the R work area by table index.
The single most damaging mistake: update the table only when the current value is GREATER than the baseline, so the higher value (wear trend) refreshes the baseline. If you invert it, an abnormal low value (air-cut after a break) poisons the baseline toward zero and every tool will false-alarm afterwards. Check the comparison direction first during commissioning.
42.6 Two-sided limits and alarm action
The upper limit is baseline x an upper-factor (an example stores 120, meaning 120% of baseline, in D2148); the fixed lower limit sits between air-cut and normal cutting load (example D2100). Never copy these numbers – measure the air-cut floor with the part removed, then record min/max cutting load over 10-20 parts and place the trip point between the bands.
On a limit breach: trigger feed hold (or a safe stop) and raise a clearly worded custom alarm stating which tool and what fault. Alarm numbers in examples (e.g. OPM170) are project-specific; check your machine’s alarm table. Add a 200-500 ms ON-delay and require the condition to persist within a defined cutting window so acceleration and entry/exit transients do not trigger it.
42.7 Three false-alarm sources and the fixes
| Source | Symptom | Fix |
|---|---|---|
| Material / stock variation | same tool load oscillates | multiple samples, envelope, margin on upper limit, fixed sampling window |
| Air cut, no engagement | load drops to idle, read as a break | gate sampling with an in-cut signal; use a sensible lower limit, not zero |
| Coolant impact / tool-change transient | load spike | ON-delay debounce; do not judge on spikes |
Mandatory verification: remove a tool or fit a deliberately broken one and run the block; confirm the alarm appears at the expected point and feed actually holds. Then run several good parts with zero false alarms. A break-detection system that has never had a forced fault injected is a gamble.

42.8 Where this fits with TM, tool setters and sensors
| Method | Basis | Cost | Catches | Misses |
|---|---|---|---|---|
| Load method (this article) | deviation from baseline | no hardware, ladder work only | break, chipping, wear trend | low-load operations, high material variation |
| Tool life management (TM) | part/time count | no hardware, built in | scheduled replacement at end of life | unexpected mid-cycle break |
| Tool setter / laser | post-cut measurement of length/diameter | hardware cost | quantified break/wear | in-process intervention |
| CT / vibration / acoustic emission | external signal features | hardware and integration cost | early wear, fine chipping | needs site calibration, hard to tune |
The usual answer is a combination: TM changes tools that reach their life, the load method stops immediately when a tool breaks early, and a tool setter spot-checks critical operations. See Fanuc tool life management and Fanuc servo load meter explained.
42.9 Commissioning checklist
- Confirm window-function instruction, control-data format and function code 153 in your PMC manual.
- Allocate free D area (control data + table) and R area (results + compare flags) in your ladder.
- Confirm parameter 4127 and write the load formula for your machine.
- Add the preset/monitor toggle and a sampling gate signal.
- Measure the air-cut floor.
- Sample normal cutting repeatedly to build the baseline table.
- Set two-sided limits from measured values.
- COMP + XMOVB – verify the “greater than updates” direction.
- Add debounce timer, feed hold, and a custom alarm text/number.
- Force a fault and verify, then confirm zero false alarms on good parts.
All addresses and alarm numbers are to be filled in from your own machine; the numbers here only illustrate the method.

Frequently Asked Questions
How can I tell a tool broke without adding any sensor?
Fanuc already has spindle-motor load data. Read the raw 2-byte value with the PMC window function (SUB51 WINDR, function code 153) into an R area, convert to percent with Load(%) = L/32767 x parameter 4127, and compare with a pre-built baseline: a collapse toward the lower limit means a broken or missing tool, while exceeding the upper limit means wear or chipping. No extra hardware is needed.
How do I set the spindle-load threshold – what percent is abnormal?
There is no universal percentage. Measure the air-cut floor (same block, part removed, same speed and feed), then record min/max cutting load over 10-20 parts and put the trip point between the maximum air-cut load and the minimum cutting load. The upper limit is often a percentage factor of the baseline (an example uses 120%) and the lower limit is a fixed value between idle and normal cutting. If the two bands differ by only a few percent near the meter resolution, use a tool setter or external power monitor instead.
How does this differ from tool life management (TM), and which should I use?
TM changes tools on a part/time count – preventive, but blind to a mid-cycle break. The load method judges actual state and can catch breaks, chipping and wear trends. They are complementary: TM changes tools that reach their life on schedule, while the load method stops immediately when a tool breaks early; a tool setter can spot-check critical operations. TM setup is covered in the linked article.
Last updated: 2026-11-24
Where to go next
- FANUC Troubleshooting — the full guide library: alarms, diagnosis numbers, servo, spindle, PMC and electrical faults, organised by symptom.
- CNC Repair Tools — which instrument measures what: multimeters, clamp meters, insulation testers and oscilloscopes, with the specification that actually matters.
- Remote Technical Support — have the readings reviewed with you: alarm reverse lookup, PMC ladder analysis and servo tuning advice by call. Repair companies and integrators welcome.
- Buying & Ownership Decisions — refurbished vs new, used-machine checks, software licensing and manuals: spend with the field facts in hand.
Read the guide, get the right instrument, or walk the diagnosis through with someone — pick whichever you need.
The original Chinese version — same procedure, with the full field notes.












































暂无评论内容