Fanuc Wire EDM / Sinker EDM: A-1ic Reverse Alarm Is Not Cutter Comp, and 317 Is an APC Battery

FANUC wire EDM and sinker EDM machines are a special-purpose category. Their alarm ranges, short-circuit detection and grounding requirements do not follow the general machining-centre table. Two misreadings waste the most time on site: treating a reverse alarm as a cutter-compensation or path problem, and treating 317 as a generic encoder communication fault before checking the battery.

Evidence level first. The root-cause conclusion below comes from a publicly documented field case that another user independently reproduced, cross-checked against alarm references. Numbers such as 1Ω / 5Ω, .030″ / .050″ gaps and torque values are field-case reference figures, not official FANUC parameters. Verify every parameter number and threshold against the manual shipped with your machine and the builder’s process sheet. This site does not host manuals, cracks or part-sales links.

广告

45.1 Start with the machine class, not the generic alarm table

Wire EDM, sinker EDM and travelling-wire machines share three traits:

  • Dedicated alarm ranges that do not map one-to-one onto general PS/SV lists.
  • Short-circuit detection, inter-electrode gap and flushing controlled by the EDM side; PMC and servo only execute.
  • Ground reference is part of the process, not an optional convenience.

So reverse the usual order: check the EDM-side state first (short indicator, flushing, gap, ground path), then look at CNC/servo alarms. Opening a general alarm table first already points you the wrong way.

45.2 A-1ic versus A-0ib: sensitivity, not a software version

The field consensus is that A-1ic short-circuit detection is more sensitive and demands a better ground path. That explains why the same R1 technology runs on an A-0ib but throws a reverse alarm on an A-1ic.

ItemA-0ib (field case)A-1ic (field case)
Short-circuit sensitivityLowerHigher
Ground resistance referenceunder 5Ω acceptableunder 1Ω required
Detection approachvoltage thresholdcurrent-sensing loop

These numbers come from a single field-case article. Use them to decide whether grounding is *obviously* bad, never as a factory spec. The portable conclusion is one sentence: A-1ic is far less tolerant of a floating or high-resistance ground, so the same wiring defect can be silent on an A-0ib and fatal on an A-1ic.

One parameter correction matters here. That widely circulated article describes parameter 1815 as a “motor overload level 0-200%” and lists 1820/1825/2003 values. This conflicts with the standard FANUC use of 1815 for absolute-position detector and reference-point setup (for example 1815#4 APZ). We do not repeat that claim. See homing failure classification for the reference-point side of this family, and verify all parameter numbers in your own manual.

45.3 Reverse alarm root cause: false short detection, not cutter comp

The classic field pattern is:

  • R1 technology throws Reverse Alarm at path reversal;
  • the short icon stays off, and the wire visibly clears the steel;
  • the same program runs fine on an A-0ib.

When all three hold, a real short and an oversized cutter compensation are both unlikely. Oversized comp normally produces an interference or path alarm, not a reverse trip with no short indication.

In a documented case, the final root cause was the red ground wire posted to the wrong point on the lower head after a rebuild. The floating reference made the short-detection circuit misread the reversal transient as a polarity fault. Another user replied that he had made the same mistake with “that one red ground wire” – a reproducible field clue, not theory.

Rule of thumb: reverse alarm + no short icon = check ground and wiring first. Do not touch cutter comp or feed parameters yet.

A-1ic reverse alarm cause chain

45.4 Four field checks: from terminal to gap

Do these in order; most “ghost” alarms reveal themselves in the first three steps:

  1. Inspect the ground terminal. Look for corrosion, looseness, or insulation trapped under the lug. In the cited case the wire was connected to the wrong point, not broken.
  2. Dedicated lug directly to the cast-iron head. Metal-to-metal contact is required; a plastic housing or coated surface does not count. Photograph routing before disassembly and use a torque tool on reassembly.
  3. Measure continuity with a milliohmmeter. From the lower head to the power-supply chassis ground bus. The case used “under 1Ω” as a rebuild check – a field reference, not an official spec.
  4. Check flushing fluid, pressure and inter-electrode gap. Insufficient flushing can create a momentary short even when the static gap is adequate. The case cites .030″ (0.76 mm) static and .050″ (1.27 mm) dynamic gaps as process references; follow your own process sheet.

After reassembly, run the exact R1 program that failed. Confirm the short icon stays off through the reversal, servo load is smooth, and the alarm does not return. A reset that “fixes” it does not count – you must complete a full reversal sequence.

Ground and gap four-step field check

45.5 Emergency workaround: A1 technology works with a cost

If the ground cannot be repaired immediately, switching R1 to A1 technology can keep production moving. A1 uses a different feed algorithm that is less sensitive to ground reference; the case author finished his clearance cuts this way.

Be explicit about the cost: A1 gives poorer corner control. It suits clearance, non-critical corner relief and slug separation, not precision die cavities. It is a bridge to shipment, not a repair conclusion. The ground still needs fixing or R1 will fail again.

45.6 Alarm 317: treat it as low APC battery first

Sources agree on the core meaning: 317/327/337… means the APC (absolute pulse coder) battery for axis n has fallen to a level requiring replacement. In “317 X ABS. Pulse Coder”, X is the reporting axis. This is not a blanket encoder communication fault, and it is not a reason to replace the servo amplifier first.

Likely causes, in field order:

CauseAction
APC backup battery exhaustedReplace battery, then re-establish the reference per procedure
Reference not set after battery changePerform reference return and rebuild absolute zero
Signal-line noise, open wire, contaminated connectorCheck encoder cable and plug, especially in coolant areas
APC interface board ageing (electrolytics etc.)Board-level test or exchange
Main / memory subsystem faultCheck parameter and SRAM backup, diagnostics and board state

Decisive test: if 317 clears after a battery change or reference return but returns at the next power-on, this is no longer a one-off lost-position event. Chase hardware: encoder cable and connector ingress, APC board capacitors, then the main board. Stop cycling power.

Also separate two battery families: 306/307 is the CNC parameter/memory backup battery, while 317 is the APC absolute-position battery. The replacement procedures and data-loss risks differ. See FANUC battery alarms 306/307 and APC and homing failures: reference not found vs wrong reference.

317 five root causes and the decisive test
广告

45.7 317 plus black screen and a red board LED: look at the main board

When 317 arrives with the following symptoms, the encoder is probably not the primary fault:

  • 317 appears on first power-up after a machine move or long idle period;
  • the LCD shows fragmented graphics, especially after a CRT-to-LCD retrofit;
  • the keyboard responds intermittently;
  • a red LED is lit next to the green power-good LED on the main board.

On FANUC 0 / 0i main boards, that red LED commonly indicates CPU halt, watchdog timeout, or memory parity/refresh error. Together with a fragmented display and an unreadable absolute position, the picture points to the main board or memory subsystem; 317 is the secondary symptom.

Order of work: confirm 24 V supply -> check parameter/SRAM backup integrity -> note exactly when the red LED lights (at power-on or later) -> only then decide between APC board, interface board and main board. For board-number reading see A16B / A17B / A20B board families. Do not swap an encoder or amplifier just because 317 is on the screen.

317 with black screen and red LED: main-board direction

45.8 Special-machine alarm family: do not copy the generic SV table

Wire EDM and sinker machines do show SV, SR and DS alarms, but the trigger conditions differ from general machines: EDM-side short detection, discharge state and flushing pressure often alarm before the servo itself. Only three things are firm in the field:

  • full CNC alarm text including prefix and axis;
  • the amplifier’s own 7-segment display;
  • the special-machine diagnostic page and short/flushing status indicators.

Public “EDM alarm cross-reference” lists are mostly single-source commercial material; this page does not reproduce them as a code table. The *method* for grounding-related SV0381-family faults is in poor grounding and the external detector alarm family, and chain dropout method is in I/O Link & PROFIBUS station dropout. Those are methods, not EDM code tables.

45.9 Grounding is not optional

Industrial EDM requires a solid ground because discharge current uses the machine structure as a reference. A poor reference affects process stability, short-detection accuracy and personal safety at the same time. Two disciplines apply:

  • Apply lockout/tagout before touching the lower head wiring and let drive capacitors discharge.
  • Make the ground path measurable and traceable: lower-head lug -> dedicated ground wire -> supply chassis ground bus, verified end to end with a milliohmmeter and recorded after reassembly.

Many “parameter faults” and “process faults” turn out to be a ground wire resting on insulation. That is the lasting lesson of the A-1ic case.

45.10 Scope

This page provides no manual PDFs, no cracked material and no part-sales links, and does not treat a third-party list as a complete code table. The 1Ω/5Ω figures, gap values and torque figures from field cases are direction indicators only; parameters and thresholds come from your manual and process sheet. Special-machine documentation is scarce, which is exactly why you need hard evidence: full screen text, the amplifier’s raw display and a measured ground path.

Frequently Asked Questions

Is a wire EDM reverse alarm a cutter-comp problem or a grounding problem?

Check the short icon. If it is off, the wire visibly clears the steel, and the same program runs on a less sensitive model such as the A-0ib, a real short and oversized cutter comp are both unlikely. In the documented A-1ic case, the red ground wire was posted to the wrong point on the lower head after a rebuild; the floating reference made short detection misread the reversal. Check terminal contact and continuity first, not cutter comp or feed parameters.

Alarm 317 cleared, but it comes back at the next power-on. What does that mean?

It is no longer a one-off lost-position event. 317 means the axis n APC battery voltage has dropped to replacement level; after a battery change and reference return it should stay cleared. If it returns at the next power-on, check encoder cable and connector ingress, APC interface board capacitors, then the main or memory subsystem. If you also see a fragmented display, dead keyboard or a red board LED, prioritise the main board.

A-0ib runs fine while A-1ic throws a reverse alarm. Software or hardware difference?

Not simply a software version. The accepted difference is that A-1ic short detection is more sensitive and needs a much better ground; the same high-resistance ground can be silent on an A-0ib and false-trigger on an A-1ic. The cited 1Ω and 5Ω figures are field references, not factory specs. Repair the ground and wiring; A1 technology can bridge production but has poorer corner accuracy and is not suitable for precision die work.

Last updated: 2026-11-25

Where to go next

Read the guide, get the right instrument, or walk the diagnosis through with someone — pick whichever you need.

Also available in Chinese: FANUC 线切割 / 电火花专机怎么修?A-1ic 反向报警真因不是刀补,317 是 APC 电池,接地门槛别照抄
The original Chinese version — same procedure, with the full field notes.
© 版权声明
THE END
喜欢就支持一下吧
点赞5赞赏 分享
评论 抢沙发

请登录后发表评论

    暂无评论内容

CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
FANUC Touchscreen / Display Unit Black or Flickering? A02B / A61L Part Numbers, 8 Faults and Replacement Steps-CNCShare | 数控电气技术中心
FANUC 触摸屏/显示单元黑屏、花屏、触摸失灵怎么修?A02B / A61L 件号怎么读 + 8 类故障速判 + 更换实操-CNCShare | 数控电气技术中心
海德汉 TNC 编程站(Programming Station)哪里下载?官方入口、版本对应、数字孪生与迁移到机床的完整流程-CNCShare | 数控电气技术中心
Fanuc G54.1 Additional Work Coordinates: P1-P48 / P1-P300, G10 L20, G52 and the Three PS0030 Boundaries-CNCShare | 数控电气技术中心
FANUC G54.1 附加工件坐标系怎么用?P1–P48 / P1–P300、G10 L20、G52 与 PS0030 三条边界-CNCShare | 数控电气技术中心
Fanuc Wire EDM / Sinker EDM: A-1ic Reverse Alarm Is Not Cutter Comp, and 317 Is an APC Battery-CNCShare | 数控电气技术中心
FANUC 线切割 / 电火花专机怎么修?A-1ic 反向报警真因不是刀补,317 是 APC 电池,接地门槛别照抄-CNCShare | 数控电气技术中心
Fanuc 16A/16B/18A/18B Legacy Machines: Alpha SVM/SPM Alarms and Obsolete Spare Strategy-CNCShare | 数控电气技术中心
FANUC 16A/16B/18A/18B 老系统伺服报警怎么查?Alpha 时代 SVM/SPM 放大器、报警对照与停产备件替代思路-CNCShare | 数控电气技术中心
Fanuc P/S Alarm 5560 and Beyond: PS5560, the 45xx Macro Family and the Official PS5523 Route-CNCShare | 数控电气技术中心
FANUC P/S 报警 5560 以后怎么查?中文补齐:PS5560 两种现场文本、45xx 宏调用族、PS5523 官方上报路径-CNCShare | 数控电气技术中心
Fanuc Tool Breakage Detection Without Extra Hardware: Spindle Load via PMC Window Function 153-CNCShare | 数控电气技术中心
文章精选
专心做好一件事
打造更优雅的WordPress主题-CNCShare | 数控电气技术中心
专心做好一件事
打造更优雅的WordPress主题