Machine Safety PL Rating Explained: ISO 13849-1 Four-Step Method – PLr Risk Graph, Category, MTTFd, DCavg, CCF and PL Verification

"The safety relay is rated PL e, so the machine is PL e." This is one of the most common – and most dangerous – statements on the shop floor. A PL is not a component nameplate value: it belongs to the whole safety function (sensor to logic to output). This article picks up where Machine safety circuits: STO vs SS1, stop categories, dual channels and EDM leaves the wiring layer, and adds the calculation layer: how to derive PLr from the risk graph, how to take the four inputs Category / MTTFd / DCavg / CCF, how to look up and verify PL, and how to fill in the verification record sheet.

The figures follow ISO 13849-1 (Annex A risk graph, Annex F common-cause-failure scoring, simplified PL chart) cross-checked against several public sources, with SIL comparison from IEC 62061. The actual project must follow the standard edition you adopt and the machine-specific risk assessment; this article gives methods, parameter bands and lookup tables, not a compliance assessment.

40.1 Two letters first: PL is what you achieve, PLr is what you need

Every argument starts here:

  • PL (Performance Level): the level a safety function actually achieves, calculated from architecture and reliability parameters, graded a to e.
  • PLr (required Performance Level): the level the risk assessment demands, derived from severity, exposure and possibility of avoidance, also graded a to e.
广告

There is only one acceptance condition: PL must be at least PLr. A function with PLr d may be built to PL d or PL e, but not PL c. One machine usually has several PLr values at once: a guard interlock may need PL d while speed monitoring in setup mode needs only PL c. PLr is defined per safety function, not as one number for the whole machine. Where a machine-specific type-C standard prescribes PLr directly, that value takes precedence.

Each PL corresponds to a band of average probability of dangerous failure per hour (PFH_D), evaluated over a 20-year mission time:

PLPFH_D (dangerous failures per hour)Rough SIL counterpart
a>= 10^-5 to < 10^-4none
b>= 3×10^-6 to < 10^-5SIL 1
c>= 10^-6 to < 3×10^-6SIL 1
d>= 10^-7 to < 10^-6SIL 2
e>= 10^-8 to < 10^-7SIL 3

40.2 Step one PLr: the S x F x P risk graph, eight combinations

PLr comes from the risk graph in Annex A of ISO 13849-1, built from three parameters:

  • S (severity): S1 is slight, normally reversible injury; S2 is serious, normally irreversible injury, including death.
  • F (frequency and duration of exposure): F1 is seldom or short exposure (rule of thumb: entering the danger zone less often than once every 15 minutes); F2 is frequent to continuous exposure.
  • P (possibility of avoiding the hazard): P1 means avoidance is possible under specific conditions; P2 means avoidance is scarcely possible.

The three parameters give eight combinations (this table is consistent across the sources checked):

SFPPLr
S1F1P1a
S1F1P2b
S1F2P1b
S1F2P2c
S2F1P1c
S2F1P2d
S2F2P1d
S2F2P2e

A widely circulated shop-floor checklist lists S2+F1+P2 as PLr c. That is wrong – the Annex A risk graph puts S2+F1+P2 at d (the neighbouring cells S2+F2+P1 and S2+F1+P2 are d and d respectively; do not copy this cell one level low). Getting this one cell wrong sets the whole safety function’s target one level too low.

The 2023 edition adds finer guidance on choosing P1 versus P2, considering the speed of hazard development, escape space, operator experience and supervision. You cannot simply relabel P2 as P1 to drop PLr from e to d – an assessor will ask you to defend it.

PLr risk graph S F P three parameters

40.3 Step two Category: architectures B, 1, 2, 3, 4 and single-fault behaviour

Category describes structure and behaviour on fault; it is not itself a PL. The five designated architectures differ like this:

CategoryStructureOn a single faultTypical implementation
BSingle channelThe safety function may be lostBasic design and component selection only
1Single channelMay still be lost, but a well-tried component and principle make it less likelyProven safety relay with positively driven contacts
2Single channel plus test channelA fault between tests may be lostPeriodic testing, test rate at least 100 times the demand rate
3Two-channel redundancyA single fault does not lose the function and is detected where reasonably practicableDual channel plus diagnostics plus CCF measures; accumulated undetected faults can still lose it
4Two-channel redundancy, high diagnosticsSingle fault detected in time; accumulated faults must not lose the functionDual channel plus DC >= 99% plus CCF; the route to PL e

The 2023 edition tightens several rules: Category 2 requires at least low diagnostic coverage (>= 60%) in each part (input, logic, output), with a test rate at least 100 times the demand rate or a test at the moment of demand; complex components such as microcontrollers never count as well-tried; and PL e may not rely solely on fault exclusion.

Category B to 4 architecture and single-fault behaviour

40.4 Step three component inputs: MTTFd three bands, DCavg four bands, CCF >= 65

With the architecture set, fill in three parameters.

MTTFd (mean time to dangerous failure) – assessed per channel, in three bands:

BandRange
Low3 years <= MTTFd < 10 years
Medium10 years <= MTTFd < 30 years
High30 years <= MTTFd <= 100 years

Each channel is capped at 100 years; you cannot buy a higher PL by quoting a reliability figure nobody can support. For electromechanical parts (contactors, switches), use the manufacturer’s B10d and the number of operations per year n_op: MTTFd = B10d / (0.1 x n_op). T10d = B10d / n_op sets the preventive replacement interval. A door switch opened a few times a day and one opened every 30 seconds may both be “high” MTTFd, but the second has a T10d of only a few years and must be scheduled for replacement.

DCavg (average diagnostic coverage) – four bands: none (<60%), low (60-90%), medium (90-99%), high (>=99%). Typical measures: test-pulse cross-monitoring of dual-channel inputs up to 99%, positively driven NC+NO auxiliary contact monitoring up to 99%, EDM feedback around output contactors about 90-99%, single channel with no monitoring = 0%. DCavg is the dangerous-failure-weighted average across subsystems; tools such as SISTEMA and PAScal compute it from a bill of materials.

CCF (common cause failure) – scored with the Annex F checklist out of 100; Categories 2, 3 and 4 require at least 65 points. Typical scored measures: physical separation of channels (up to about 15 points), diversity using different technologies or manufacturers (up to about 20 points), protection against over-voltage, over-current and over-temperature, designer competence and training, and environmental control (temperature, humidity, vibration, EMC). Two channels on the same PCB and the same 24 V supply can fail together from one short circuit – no amount of redundancy helps.

MTTFd DCavg CCF three inputs

40.5 Step four look up PL from Category x DCavg x MTTFd, then verify PL >= PLr

Put the results into the simplified PL chart (the table below is consistent across the sources checked):

Category / DCavgMTTFd lowMTTFd mediumMTTFd high
B / noneab–
1 / none––c
2 / lowabc
2 / mediumbcd
3 / lowbcd
3 / mediumcdd
4 / high––e

Compare the resulting PL with PLr from step one: only PL >= PLr passes. A safety function is a series chain of input (sensor), logic (safety relay or safety PLC) and output (contactor or drive), and the total PL is limited by the weakest subsystem; summing the PFH_D values of the parts gives the total PFH_D.

Two cautions: different editions (2006, 2015, 2023) change chart boundaries and limiting conditions, so use the original chart from the edition adopted for the project; and this simplified table only gives band-level lookup. To claim PL e or to build a full argument, use a tool such as SISTEMA for a complete PFH_D calculation.

PL lookup and verification quick reference

40.6 Three upgrade paths when PL falls short

When PL < PLr, take these routes from cheapest to most effective:

  1. Change the architecture: move from a single channel to dual channel (Category 2 to 3/4). This is the most effective step, but CCF separation must come with it.
  2. Use higher-MTTFd components: replace a low-band door switch or contactor with one whose datasheet gives B10d and a high-band MTTFd, or reduce the operating frequency so T10d grows.
  3. Improve CCF and diagnostics: separate channel routing, over-voltage/current protection, add EDM readback and test pulses, lift the CCF score past 65 and move DCavg up a band.
广告

If all three fail, go back to the risk assessment – check whether PLr was set too high (can the P2 judgement be defended?) instead of forcing the calculation to fit.

40.7 Two recurring traps: a PL e relay does not make a PL e machine; CE/UL is not a substitute

Trap one: a relay marked PL e means the machine is PL e. It does not. PL belongs to the whole safety function. A Category 3 dual-channel arrangement can land anywhere from b to e depending on MTTFd and DCavg – the same Category means different results with different component data and diagnostics. A weak door switch, logic unit or output contactor drags the whole chain down to the weakest link.

Trap two: a CE or UL mark, or a routine electrical safety test, removes the need for a PL assessment. It does not. CE marking is a regulatory conformity declaration and UL is a product safety certification; neither replaces the ISO 13849-1 PL assessment of a safety function, and a correct PL calculation does not waive other regulatory duties. They run in parallel.

40.8 Relationship to SIL: PL a-e and SIL 1-3

IEC 62061 grades safety functions with SIL, running in parallel with PL: PL a has no SIL counterpart; PL b/c roughly correspond to SIL 1, PL d to SIL 2 and PL e to SIL 3. These are order-of-magnitude comparisons, not a conversion formula – the input parameters, failure measures and decision paths differ, so you cannot swap one table for another. Subsystems from both standards may be combined in one machine, but each must be assessed and documented on its own.

In practice, European machine builders and CE export projects tend to use the PL language of ISO 13849-1, while process industry and some safety-PLC datasheets quote SIL. On an export project, ask which language the customer or machine standard requires before choosing which method to calculate and document.

40.9 Architecture quick reference – continue from the wiring article

ArchitectureTypical achievableBypass resistanceDiagnostic coverageWiring complexityCost
Dedicated safety relayPL d / e (depends on model)MediumMedium to high (EDM readback)MediumLow to medium
Safety PLC (PROFIsafe / CIP Safety / Safety over EtherCAT)PL e / SIL 3HighHighMedium (bus plus parameterisation)High
Ordinary PLC output used for safetyNot recommended for a high PL claimLowLowLowLow
Mixed (safety relay plus safety PLC)up to PL eHighHighHighHigh

For the actual STO/SS1 wiring, dual channels and EDM readback of each architecture, see Machine safety circuits: STO vs SS1, stop categories, dual channels and EDM; for the Fanuc emergency-stop signal chain see Fanuc emergency stop circuit; for a Heidenhain guard interlock chain see Heidenhain guard doors open alarm; for Siemens Safety Integrated alarms see 840D sl Safety Integrated alarms.

40.10 Verification and records: functional tests, single-fault injection, EDM readback

Calculating a PL is not the end – the function must be verified and recorded:

  1. Functional tests: emergency stop, guard door, light curtain and STO drop-out – test each for trigger, stop, no automatic restart, and recovery only by the prescribed reset.
  2. Single-fault injection: on each channel, open one wire, short to 24 V, and simulate a stuck contact; verify that a single fault does not lose the safety function and is detected or annunciated.
  3. EDM readback: confirm that the actual contactor state matches the command and that the reset circuit cannot bypass it.

Suggested record-sheet fields (copy into your test procedure as a starting point):

IDSafety functionPLrmeasured PLTrigger deviceStop timeSingle-fault injection resultEDM readbackVerdictTester/date
F01Emergency stopddE-stop buttonfill in measuredopen/stuck, each itemOK / faultpass / fixfill in
F02Guard interlockddGuard switchfill in measuredopen/short, each itemOK / faultpass / fixfill in
F03Light curtaind–OSSDfill in measuredblocking/short, each itemOK / faultpass / fixfill in
F04STO drop-outd–Safety relayfill in measuredchannel 1/2 opened separatelyOK / faultpass / fixfill in

This is a sample template organised around the verification stage of ISO 13849-1; adapt fields and acceptance thresholds to your risk assessment and the standard edition in use.

40.11 Export-compliance view: what to prepare for the CE technical file

For CE export projects, the safety-related part of the file normally needs to show:

  • The machine risk assessment and a list of safety functions, each with PLr and its justification.
  • The PL calculation: architecture, MTTFd / DCavg / CCF values and their sources (B10d, T10d and diagnostic-coverage data from component datasheets).
  • The CCF scoring sheet (Annex F, item by item, at least 65 points).
  • Verification records (the test table above) and the maintenance plan (replace at T10d).
  • Manufacturer declarations of conformity and datasheet pages for safety-related components.

This article gives a method framework and band-level lookup only, not legal or certification advice; formal projects must follow the original text of the adopted standard edition and the requirements of your notified body or customer.

Frequently Asked Questions

What is the difference between PL and PLr, and does a PL e safety relay make the machine PL e?

PL is the level a safety function actually achieves, calculated from architecture and component data; PLr is the level required by the risk assessment, derived from the S/F/P risk graph; the acceptance condition is PL >= PLr. PL belongs to the whole sensor-to-logic-to-output chain, not to one component: if the guard switch or output contactor has only low-band MTTFd/DC, the chain cannot reach PL e even when the relay is rated PL e.

What PL can a Category 3 dual-channel circuit reach, and why?

On the simplified PL chart, Category 3 with low DCavg gives PL b/c/d depending on MTTFd, and Category 3 with medium DCavg gives PL c/d/d – so in the simplified table Category 3 is normally capped at d, and PL e goes through Category 4 or a full PFH_D calculation. The reason is that dual channels only guarantee that a single fault does not lose the function; accumulated undetected faults can still do so, and DCavg plus MTTFd determine which band it lands in.

Does an emergency stop need dual channels, and how do I choose stop category 0 or 1?

Whether dual channels are needed follows the PLr of that particular emergency-stop function: PLr d/e normally needs dual-channel redundancy with diagnostics, while a low PLr can use a single channel. As for Cat 0 / Cat 1, note that these are stop categories from IEC 60204-1, a completely different classification from the ISO 13849-1 architecture Categories B/1/2/3/4 – do not mix them. Cat 0 removes power to the actuators immediately (uncontrolled stop); Cat 1 makes a controlled decelerating stop and removes power only once stopped. Choose Cat 1 where inertia or process needs a controlled stop and Cat 0 where the hazardous motion must be removed immediately, per the risk assessment and the machine standard.

Last updated: 2026-11-24

Where to go next

Read the guide, get the right instrument, or walk the diagnosis through with someone — pick whichever you need.

Also available in Chinese: 机床安全回路 PL 等级到底怎么定?ISO 13849-1 四步法:PLr 风险图 → Category/MTTFd/DCavg/CCF → PL 验证(附测试记录表)
The original Chinese version — same procedure, with the full field notes.
© 版权声明
THE END
喜欢就支持一下吧
点赞12赞赏 分享
评论 抢沙发

请登录后发表评论

    暂无评论内容

CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
FANUC Touchscreen / Display Unit Black or Flickering? A02B / A61L Part Numbers, 8 Faults and Replacement Steps-CNCShare | 数控电气技术中心
FANUC 触摸屏/显示单元黑屏、花屏、触摸失灵怎么修?A02B / A61L 件号怎么读 + 8 类故障速判 + 更换实操-CNCShare | 数控电气技术中心
海德汉 TNC 编程站(Programming Station)哪里下载?官方入口、版本对应、数字孪生与迁移到机床的完整流程-CNCShare | 数控电气技术中心
Fanuc G54.1 Additional Work Coordinates: P1-P48 / P1-P300, G10 L20, G52 and the Three PS0030 Boundaries-CNCShare | 数控电气技术中心
FANUC G54.1 附加工件坐标系怎么用?P1–P48 / P1–P300、G10 L20、G52 与 PS0030 三条边界-CNCShare | 数控电气技术中心
Fanuc Wire EDM / Sinker EDM: A-1ic Reverse Alarm Is Not Cutter Comp, and 317 Is an APC Battery-CNCShare | 数控电气技术中心
FANUC 线切割 / 电火花专机怎么修?A-1ic 反向报警真因不是刀补,317 是 APC 电池,接地门槛别照抄-CNCShare | 数控电气技术中心
Fanuc 16A/16B/18A/18B Legacy Machines: Alpha SVM/SPM Alarms and Obsolete Spare Strategy-CNCShare | 数控电气技术中心
FANUC 16A/16B/18A/18B 老系统伺服报警怎么查?Alpha 时代 SVM/SPM 放大器、报警对照与停产备件替代思路-CNCShare | 数控电气技术中心
Fanuc P/S Alarm 5560 and Beyond: PS5560, the 45xx Macro Family and the Official PS5523 Route-CNCShare | 数控电气技术中心
FANUC P/S 报警 5560 以后怎么查?中文补齐:PS5560 两种现场文本、45xx 宏调用族、PS5523 官方上报路径-CNCShare | 数控电气技术中心
Fanuc Tool Breakage Detection Without Extra Hardware: Spindle Load via PMC Window Function 153-CNCShare | 数控电气技术中心
文章精选
专心做好一件事
打造更优雅的WordPress主题-CNCShare | 数控电气技术中心
专心做好一件事
打造更优雅的WordPress主题