58.1 Accuracy verification is not accuracy preservation
| Aspect | Accuracy verification | Accuracy preservation |
|---|---|---|
| Purpose | Acceptance, post-overhaul re-check, capability confirmation | Routine drift prevention, early anomaly detection |
| Cycle | One-off / annual / after overhaul | Daily / weekly / monthly / quarterly / semiannual / annual |
| Tools | Laser interferometer, ballbar, precision straightedge | Senses + dial indicator + simple gauges + record sheet |
| Environment | Temperature controlled, stable foundation | Shop floor is fine |
| Cost | High (instrument + downtime) | Almost zero (labor + records) |
| Site coverage | /3425, /4085 | This article |
Remember one line: verification answers “is this machine good enough”; preservation answers “is it quietly getting worse”.

58.2 Why accuracy drifts: seven paths
- Screw wear and preload loss: backlash grows, repeatability worsens.
- Insufficient way lubrication: friction rises, stick-slip, local wear.
- Thermal drift: spindle and screw grow with heat; morning and afternoon parts differ.
- Tool compensation and mechanical clearance: compensation not following real wear.
- Datum surface cleanliness: chips or burrs on the datum stone make every measurement wrong.
- Grounding and interference: poor grounding triggers servo alarm families (see the Chinese companion on SV0381/0384).
- Geometric change after a crash: collisions can permanently alter geometry; recheck per /2193-style three-way diagnosis.
Drift does not happen all at once — the value of inspection is catching it while it is still only a trend.
58.3 Daily check (3–5 minutes)
| Item | Method | Criterion (check against machine manual) |
|---|---|---|
| Home each axis once | Check machine coordinate after homing | Repeatable, no abnormal offset |
| Spindle / feed noise | Listen and feel | No periodic noise, no friction squeal |
| Oil level / pressure | Sight glass, gauge | Within the manual's normal range |
| Alarm log | Review recent alarm history | No new unhandled alarms |
| Chips / coolant | Visual clean-up | No chips on ways or datum surfaces |
Table 58-1 Daily items (3–5 minutes, operator)

58.4 Weekly check (~30 minutes)
- Way lubrication: confirm lubrication travel and oil film, no blocked lines.
- Air pressure and coolant concentration: pressure in range, coolant concentration valid and not degraded.
- E-stop and door interlock function: press and test every time — confirm the circuit really opens, not just that a message appears.
- Clamp and unclamp pressure: tool clamp/release pressure within spec.
- Chip conveyor and coolant circuit: clean the conveyor, check pump and lines for leaks.
58.5 Monthly check (1–2 hours)
- Soft limit vs hard limit position: confirm the soft limit is effective before the hard limit.
- Home dog and deceleration switch: check position and fastening; looseness causes homing drift.
- Door interlock and safety circuit: door switch and interlock function.
- Spindle radial runout, two-point method: remeasure per Spindle Runout and log the trend.
- Backlash quick recheck: remeasure with the dial-indicator method and log whether it exceeds tolerance.
Record trends, not just pass/fail — a trend warns earlier than a single passing value.
58.6 Quarterly and semiannual check
- Geometric accuracy spot check: ballbar (ISO 230-4) / laser (ISO 230-2); method in the accuracy-verification article, criteria principle in Geometric Accuracy Framework.
- Pitch error compensation recheck: confirm compensation values are still valid.
- Battery and absolute encoder backup: check battery state to avoid losing zero on replacement.
- Electrical cabinet temperature and cooling: filter cleaning, fan operation, cabinet temperature trend.
- Contactor and relay pull-in test: contact state, reliable pull-in.
- Ground resistance: measure against the machine electrical manual’s grounding requirement.
58.7 Annual check
- Full machine geometry recheck and compensation update: by qualified personnel per ISO 230; update pitch compensation and other values.
- Complete safety circuit verification: confirm safety functions still meet the originally designed level, following the PL-grade approach (CN companion article).
- Spare parts inventory and discontinued-part substitution: consumables and obsolete boards; substitution ideas in the Chinese companion articles.
58.8 Record sheet template (printable)
| Cycle | Item | Method | Criteria source | Measured | Result | Handler | Date |
|---|---|---|---|---|---|---|---|
| Daily | Home each axis | Check machine coordinate | Machine manual | ___ | □OK □NG | ___ | ___ |
| Weekly | E-stop / door | Press and test each time | Safety circuit drawing | ___ | □OK □NG | ___ | ___ |
| Monthly | Backlash | Dial indicator method | Machine manual | ___ | □OK □NG | ___ | ___ |
| Quarterly | Geometry | Ballbar / laser (ISO 230) | ISO 230 | ___ | □OK □NG | ___ | ___ |
| Annual | Safety circuit | Full verification | PL-grade design | ___ | □OK □NG | ___ | ___ |
Table 58-2 Inspection record sheet template (one row per item, print and fill in)
🔴 Criteria-source discipline: the criteria column must say “per machine manual / ISO 230, checked item by item”, never a fixed universal value — tolerance grades and machines differ by an order of magnitude, and a hard-coded number would mislead. This follows the same principle as the geometric-accuracy framework.
58.9 What to do when an anomaly is found: mechanical / electrical / parameter three-way split
When an inspection exceeds tolerance, split into three paths before touching parameters:
- Mechanical: clearance, preload, lubrication, datum surface, fasteners — check for physical change first.
- Electrical: grounding, interference, servo alarm families, terminals.
- Parameter: only after mechanical and electrical are ruled out, review compensation parameters and tool compensation.
This follows the same thinking as the site’s crash-diagnosis three-way split: preserve the scene, split the paths, then act.

58.10 Paper vs electronic record + site cross-references
- Paper sheet hung on the machine: operator ticks and signs on the spot, good for daily/weekly checks; downside is trend analysis is awkward.
- Excel sheet: good for logging measured values and plotting trends, suited to monthly/quarterly/annual data.
- Hybrid: paper for daily/weekly, electronic from monthly onward — the practical choice for most shops.
Recommended: start with the printable sheet from this article as a wall chart, then enter monthly/quarterly/annual data into a spreadsheet to watch trends.
Site cross-references: Machine Electrical Inspection Checklist; geometric accuracy framework /4085; spindle runout /4103; accuracy verification method (CN companion); backlash and pitch compensation (CN companions); safety circuit PL grade (CN companion).

Frequently Asked Questions
What is the difference between accuracy preservation and ISO 230-2 accuracy verification? Do I need both?
Yes, both. Accuracy verification (ISO 230-2/230-4) is acceptance and post-overhaul re-check using a laser/ballbar in a qualified environment, answering “is this machine good enough”. Accuracy preservation is routine inspection with simple tools and a record sheet on the shop floor, answering “is it quietly getting worse”. The former sets the capability baseline; the latter protects it. Neither replaces the other.
What should a daily machine inspection include, and how often?
By six cycles: daily (3–5 min) home each axis, noise, oil level, alarm log, chip cleanup; weekly (30 min) way lubrication, air pressure, E-stop/door (press and test every time), clamp pressure, coolant circuit; monthly backlash and spindle runout quick rechecks; quarterly/semiannual geometry spot check, compensation recheck, battery and cabinet; annual full geometry recheck and complete safety circuit verification. Confirm items and criteria against your machine manual.
How often should backlash and pitch error compensation be rechecked, and how are criteria set?
Backlash: monthly quick recheck, quarterly trend confirmation. Pitch error compensation: quarterly spot check, annual recheck and update. Criteria must be checked against the machine manual and ISO 230 item by item — tolerance grades and machines differ by an order of magnitude, so this article gives no universal number. Measurement methods are covered in the Chinese companion articles on backlash (/1597) and pitch compensation (/1613).
Last updated: 2026-11-26
Where to go next
- FANUC Troubleshooting — the full guide library: alarms, diagnosis numbers, servo, spindle, PMC and electrical faults, organised by symptom.
- CNC Repair Tools — which instrument measures what: multimeters, clamp meters, insulation testers and oscilloscopes, with the specification that actually matters.
- Remote Technical Support — have the readings reviewed with you: alarm reverse lookup, PMC ladder analysis and servo tuning advice by call. Repair companies and integrators welcome.
- Buying & Ownership Decisions — refurbished vs new, used-machine checks, software licensing and manuals: spend with the field facts in hand.
Read the guide, get the right instrument, or walk the diagnosis through with someone — pick whichever you need.
The original Chinese version — same procedure, with the full field notes.












































暂无评论内容