FANUC PMC / Siemens S7 / Mitsubishi FX Ladder Mnemonic and Address Cross-Brand Reference: Same Function, Three Notations + Address Map + Ladder Symbols

Bottom line: the same logic is written completely differently in three brands — copying an electrical drawing across brands always fails. FANUC PMC uses RD/AND/OR/WRT, Siemens S7 uses A/AN/O/=, Mitsubishi FX uses LD/AND/OR/OUT. They look similar, but the details — edge detection, block logic, assign symbols, timer time bases — are all traps. This reference puts basic instructions, function instructions and address types side by side, and covers the F/G signal direction that Chinese-language sources most often get backwards. All mnemonics and address ranges follow the programming manual for your specific model; this is a quick-reference index, not a program template to copy.

57.1 Why a cross-brand reference: same function, three notations

ScenarioWhat copying doesCorrect approach
Porting FANUC ladder logic to S7Mnemonics differ, and F/G addresses have no meaning in S7Map function by function, rewrite addresses
Reading an imported machine's electrical drawingAddress symbols belong to another brand's systemIdentify the brand first, then look up its address types
Retrofit / migrationTimer time bases and edge syntax differ, so timing goes wrongCross-check the function table, then verify item by item
广告

Remember one line: logic functions can be ported across brands; mnemonics and addresses cannot be copied across brands.

Cross-brand ladder landscape

57.2 Basic logic instructions

FunctionFANUC PMCSiemens S7 (STL)Mitsubishi FX
NO contact (load/read)RDA (and; first contact also A)LD
NC contactRD.NOTANLDI
Contact in series (and)ANDAAND
NC in seriesAND.NOTANANI
Contact in parallel (or)OROOR
NC in parallelOR.NOTONORI
Coil outputWRT= (assign)OUT
Set / resetSET / RSTS / RSET / RST

Table 57-1 Basic logic instructions across brands (mnemonics per model manual)

⚠️ Do not be fooled by “looking the same”: FANUC’s AND/OR share names with Mitsubishi’s, but FANUC reads a coil with WRT, Mitsubishi with OUT, Siemens with = — the output instruction differs in all three. S7’s A/AN/O/ON are Boolean instructions working on accumulators, not a literal one-to-one match with ladder symbols.

57.3 Function instructions

FunctionFANUC PMCSiemens S7Mitsubishi FX
TimerTMR (function instruction)SD (on-delay) / SS (retentive)TMR (OUT T + constant K)
CounterCTRCD (down count) etc.OUT C + K
CompareCMP familycompare instructions / L + compareCMP family
Data moveMOV familyL (load) / T (transfer)MOV
Rising / falling edgeDIFU / DIFDEU / EDLDP / LDF
Block logic merge—OLD (OR block) / AN (AND block context)ORB / ANB

Table 57-2 Function instructions across brands

🔴 Timer time base is the most hidden trap: Mitsubishi FX’s TMR constant is a 100 ms step (K10 = 1 s), while Siemens S7-1200 TON PT is in ms (PT=1000 is 1 s). The same digits 100 mean 10 seconds in one and 0.1 second in the other — always check the time base against each manual during migration; this is a frequent cause of wrong action timing. Specific timer numbers and time bases follow your model manual.

57.4 Address types

PurposeFANUC PMCSiemens S7Mitsubishi FX
Machine-to-controller inputX (MT→PMC)I (input)X
Controller-to-machine outputY (PMC→MT)Q (output)Y
Internal relayRM (bit memory)M
Retentive relayKM retentive area / DBM retentive area
Timer / counterT / CT / CT / C
Data table / data blockD (data table)DB (data block)D (data register)
Message requestA——

Table 57-3 Address types across brands (type-level mapping only, not address-number conversion)

⚠️ This is a type-level mapping, not an address-number conversion: FANUC’s X12.5 has no automatic equivalence to Siemens’ I12.5; change the I/O Link or hardware configuration and the bit address changes. Addresses must be reassigned and verified point by point during migration.

57.5 F / G signal direction: the one Chinese sources most often reverse

G/F direction diagram

FANUC PMC and CNC exchange data through dedicated registers, with a fixed direction defined by FANUC that the PMC programmer can only use, not change:

  • G = PMC → CNC: commands PMC writes to CNC (cycle start, feed hold, auxiliary-function complete). Used as a coil and also as a contact.
  • F = CNC → PMC: status CNC writes to PMC (current mode, alarm state, M-code decode result, servo-on status). Used only as a contact, never as a coil — think of “F” as From CNC.

Memory aid: X/Y are physical signals between machine side and PMC (X in, Y out, assigned by I/O Link); F/G are logical signals between PMC and CNC (bound by CNC software version). X/Y bit numbers follow hardware; G/F meanings follow the system — confusing the two sends troubleshooting in the wrong direction.

🔴 Chinese-language material often reverses G and F. Check against the official PMC programming manual address table (e.g. the B-61863E series): X=MT→PMC, Y=PMC→MT, F=NC→PMC, G=PMC→NC. Your machine manual governs.

57.6 Same function side by side: start-stop self-hold in three notations

Take “press start, then self-hold” as an example (illustrative; addresses per actual assignment):

  • FANUC PMC: RD X1.0 (start) → OR R100.0 (self-hold) → AND.NOT X1.1 (stop NC) → WRT R100.0 (hold bit).
  • Siemens S7 (STL): A I0.0 → O M0.0 → AN I0.1 → = M0.0.
  • Mitsubishi FX: LD X0 → OR M0 → ANI X1 → OUT M0.

Table 57-4 Start-stop self-hold in three notations (same function, different syntax)

广告

All three are functionally identical, but the output instruction, address prefix and NC-contact form all differ. Copying any one into another brand will fail to compile or reverse the action.

57.7 Scan cycle and execution model differences

  • FANUC PMC: deterministic cyclic scan, typical scan time about 5–20 ms (visible on the PMC diagnostic screen), varying by PMC model (SA1/SA3/SB7 etc.) — check your model and diagnostic screen.
  • Siemens S7: configurable scan cycle, commonly 1–100 ms depending on CPU and configuration.
  • Mitsubishi FX: cyclic scan determined by program steps (END affects scan length).

Key point: the scan cycle directly affects whether a short signal is missed. A momentary button press or pulse shorter than one scan may not be captured — when troubleshooting “the signal occasionally does not actuate”, check scan time and signal width before suspecting the wiring.

57.8 Five migration pitfalls

Five migration pitfalls
  1. G/F direction reversed — G is PMC→CNC, F is CNC→PMC; F cannot be a coil.
  2. Type mapping treated as address conversion — X12.5 is not I12.5; addresses must be reassigned.
  3. Timer constants copied verbatim — FX 100 ms steps vs S7 ms, a hundredfold difference.
  4. Edge instruction syntax differs — FANUC DIFU/DIFD, S7 EU/ED, Mitsubishi LDP/LDF, not interchangeable.
  5. Copying the electrical drawing — symbols belong to one brand’s system; a different system needs rewritten logic and item-by-item verification.

Compliance boundary: this article covers mnemonic and address-type cross-referencing and syntax differences only. It provides no cracks, password bypasses, pirated manuals or download mirrors; specific instructions and address ranges follow each brand’s model programming manual.

57.9 Site cross-references and how to use this

Recommended workflow: find the three-brand notation by function here, go back to /1295 and /1079 for FANUC symbol detail, then confirm instructions and address ranges in the official programming manual for the target brand. All three steps matter.

Three-page workflow

Frequently Asked Questions

For FANUC, which is the signal PMC sends to CNC: G or F?

G is PMC→CNC (a command, usable as both coil and contact); F is CNC→PMC (CNC status, usable only as a contact, never as a coil). Chinese-language sources often reverse them; check the official PMC programming manual address table.

Can I directly change a FANUC ladder’s X12.5 into a Siemens I12.5?

No. The mapping here is type-level (input to input, output to output), not address-number conversion. FANUC’s X bit numbers come from I/O Link assignment, Siemens’ I addresses from hardware configuration — there is no automatic conversion. Migration requires reassigning addresses and verifying point by point.

Why does the same timer constant produce very different times in Mitsubishi and Siemens?

Because the time bases differ. Mitsubishi FX’s TMR constant is a 100 ms step (K10 = 1 s), while Siemens S7-1200 TON’s PT is in ms (PT=1000 is 1 s). The same digits 100 differ a hundredfold. When porting timers, always check the time base and timer number against each manual.

Last updated: 2026-11-26

Where to go next

Read the guide, get the right instrument, or walk the diagnosis through with someone — pick whichever you need.

© 版权声明
THE END
喜欢就支持一下吧
点赞12赞赏 分享
评论 抢沙发

请登录后发表评论

    暂无评论内容

CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
CNC电气调试问题解答 | 数控机床电气工程师资料共享屋
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
图片-CNCShare | 数控电气技术中心
FANUC SV0005 Sync-Axis Error and Alarm 5046 Straightness Compensation: M/S/C Segment Diagnosis and Parameter Checklist-CNCShare | 数控电气技术中心
FANUC SV0005 同步轴误差与 5046 直线度补偿怎么查?M/S/C 段判定 + 参数自检清单-CNCShare | 数控电气技术中心
FANUC Tool Nose Orientation T0–T9: Imaginary Tool-Tip Direction, 45° Chamfer Error and the Root Cause of Taper Oversize-CNCShare | 数控电气技术中心
FANUC 刀尖方位号 T0–T9 怎么定?假想刀尖方向表 + 45° 倒角残留误差算例 + 锥面超差根因-CNCShare | 数控电气技术中心
CNC Machine Accuracy Preservation: Preventive Maintenance Checklist — Daily / Weekly / Monthly / Quarterly / Semiannual / Annual Cycles with Items, Criteria and Printable Record Sheet-CNCShare | 数控电气技术中心
数控机床精度保持怎么做?预防性维护点检清单:日/周/月/季/半年/年度六级周期 × 检测项目 × 判据 × 记录表(可打印)-CNCShare | 数控电气技术中心
FANUC PMC / Siemens S7 / Mitsubishi FX Ladder Mnemonic and Address Cross-Brand Reference: Same Function, Three Notations + Address Map + Ladder Symbols-CNCShare | 数控电气技术中心
FANUC PMC / 西门子 S7 / 三菱 FX 梯形图助记符与地址类型跨品牌对照总表:同一功能三种写法 + 地址映射 + 梯形图符号对照-CNCShare | 数控电气技术中心
FANUC / SINUMERIK / Mitsubishi Macro and System Variable Cross-Brand Reference: Date, Tool Compensation, G54–G59, Common # Numbers-CNCShare | 数控电气技术中心
FANUC / 西门子 / 三菱 宏变量与系统变量跨品牌对照总表:日期时间 / 刀长刀补 / G54–G59 工件坐标 / 常用 # 号一次查全-CNCShare | 数控电气技术中心
Heidenhain TNC Safety Alarms: 126-xxxx Self-Test and Configuration, 1C7-xxxx MC Drives and SPLC, 230-0005 External Emergency Stop-CNCShare | 数控电气技术中心
海德汉 TNC 安全报警怎么查?126-xxxx 自检与安全配置 + 1C7-xxxx MC 驱动与 SPLC + 230-0005 外部急停(三族逐条对照)-CNCShare | 数控电气技术中心
文章精选
专心做好一件事
打造更优雅的WordPress主题-CNCShare | 数控电气技术中心
专心做好一件事
打造更优雅的WordPress主题