排序
SINUMERIK 828D Tool Management NC-PLC Interface Explained: DB4300, Three Tables and the Drum-Magazine Wrong-Tool Case
Following the 828D DB quick reference, this explains the interface logic: the NCK-tool-management-to-PLC handshake, DB4300 job/command bits, the DB9900/9901/9902 table roles, 1:1 v...
SINUMERIK 828D User Alarm Bits: DB1600 Sequential Mapping and Extended 701000-701999
The SINUMERIK 828D user alarm bit address reference: the DB1600 sequential mapping contrasted item by item with the 840D DB2 grouped algorithm (700247 is DB1600.DBX30.7 on the 828D...
FANUC PMC Functional Instruction (SUB) Quick Reference: Numbers, Families and Model Availability
PMC functional instructions are called by SUB number, but the same SUB number is not available on every PMC model. Verifiable SUB numbers and families from official Table 5(a), rea...
Fanuc Macro B Guide: Variable Partitions, G65/G66/G67 Calls, Nesting Limits and PS Alarm Codes
A complete Fanuc Custom Macro B guide: choosing the right variable partition (#1-#33 local variables cleared at return, #100-#199 common variables cleared at power off, #500-#999 r...
FANUC M98 / M99 Subprogram Calls: P Numbers, Nesting Limits and How to Troubleshoot Alarms 076 / 077 / 078
FANUC M98/M99 subprogram calls explained: four P-number formats, L repeat counts, the boundary between NC M98/M99 and PMC SUB, three uses of M99, and the conflicting nesting limits...
Machine Safety Circuits: STO vs SS1, Stop Categories, PL / SIL, Dual Channels and EDM
A circulating brief attributes Cat0 / Cat1 / Cat2 / Cat3 to ISO 13849. That merges two different meanings of category: stop categories 0/1/2 come from IEC 60204-1, architecture cat...
How to Read a CNC Machine Electrical Schematic – Symbols, Wire Numbers, Power/Control Circuits, and Tracing an Alarm via PMC Address
A practical method for reading any CNC electrical schematic - common symbols and designations, wire/sheet numbers as coordinates, how to read the power and control circuits, and ho...
Inductive Proximity Switches for CNC Machines: NPN vs PNP vs NAMUR and Their Roles as Hard Limits, Reference Switches and Tool Presence Sensors
Inductive proximity switches in three CNC roles - hard limit, reference switch and tool presence - with different selection rules for each. Covers why PNP suits new sourcing-input ...
FANUC SV0381/0384/0385/0386/0387 Servo Alarms: Poor Grounding and the Linear Scale (EXT) Alarm Family
On a full-closed-loop machine SV0381/0384/0385/0386/0387 often trip alternately or keep repeating on one axis, easily misread as a broken scale or amplifier. These alarms all say '...
Bypassing a FANUC Linear Scale: Full to Semi Closed-Loop Conversion with 1815#1, 2024, 2084/2085 and 2185
How to temporarily bypass a FANUC linear scale and switch from full to semi closed-loop: 1815#1/#5, 2024, 2084/2085, 2185, 1821, 1850, 1851/1852, 2003#5 and 2019#7. Marks the dispu...