English 第6页
FANUC / CNC technical articles in English
Looking for a curated starting point instead of the full post list? → FANUC & CNC Troubleshooting Guides (English) groups every English article by topic with a FAQ.
SINUMERIK 828D Tool Management NC-PLC Interface Explained: DB4300, Three Tables and the Drum-Magazine Wrong-Tool Case-CNCShare | 数控电气技术中心

SINUMERIK 828D Tool Management NC-PLC Interface Explained: DB4300, Three Tables and the Drum-Magazine Wrong-Tool Case

Following the 828D DB quick reference, this explains the interface logic: the NCK-tool-management-to-PLC handshake, DB4300 job/command bits, the DB9900/9901/9902 table roles, 1:1 v...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
0628
SINUMERIK 828D User Alarm Bits: DB1600 Sequential Mapping and Extended 701000-701999-CNCShare | 数控电气技术中心

SINUMERIK 828D User Alarm Bits: DB1600 Sequential Mapping and Extended 701000-701999

The SINUMERIK 828D user alarm bit address reference: the DB1600 sequential mapping contrasted item by item with the 840D DB2 grouped algorithm (700247 is DB1600.DBX30.7 on the 828D...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
0797
FANUC PMC Functional Instruction (SUB) Quick Reference: Numbers, Families and Model Availability-CNCShare | 数控电气技术中心

FANUC PMC Functional Instruction (SUB) Quick Reference: Numbers, Families and Model Availability

PMC functional instructions are called by SUB number, but the same SUB number is not available on every PMC model. Verifiable SUB numbers and families from official Table 5(a), rea...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
06114
Fanuc Macro B Guide: Variable Partitions, G65/G66/G67 Calls, Nesting Limits and PS Alarm Codes-CNCShare | 数控电气技术中心

Fanuc Macro B Guide: Variable Partitions, G65/G66/G67 Calls, Nesting Limits and PS Alarm Codes

A complete Fanuc Custom Macro B guide: choosing the right variable partition (#1-#33 local variables cleared at return, #100-#199 common variables cleared at power off, #500-#999 r...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
06512
FANUC M98 / M99 Subprogram Calls: P Numbers, Nesting Limits and How to Troubleshoot Alarms 076 / 077 / 078-CNCShare | 数控电气技术中心

FANUC M98 / M99 Subprogram Calls: P Numbers, Nesting Limits and How to Troubleshoot Alarms 076 / 077 / 078

FANUC M98/M99 subprogram calls explained: four P-number formats, L repeat counts, the boundary between NC M98/M99 and PMC SUB, three uses of M99, and the conflicting nesting limits...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
02914
Machine Safety Circuits: STO vs SS1, Stop Categories, PL / SIL, Dual Channels and EDM-CNCShare | 数控电气技术中心

Machine Safety Circuits: STO vs SS1, Stop Categories, PL / SIL, Dual Channels and EDM

A circulating brief attributes Cat0 / Cat1 / Cat2 / Cat3 to ISO 13849. That merges two different meanings of category: stop categories 0/1/2 come from IEC 60204-1, architecture cat...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
0589
How to Read a CNC Machine Electrical Schematic - Symbols, Wire Numbers, Power/Control Circuits, and Tracing an Alarm via PMC Address-CNCShare | 数控电气技术中心

How to Read a CNC Machine Electrical Schematic – Symbols, Wire Numbers, Power/Control Circuits, and Tracing an Alarm via PMC Address

A practical method for reading any CNC electrical schematic - common symbols and designations, wire/sheet numbers as coordinates, how to read the power and control circuits, and ho...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
06511
Inductive Proximity Switches for CNC Machines: NPN vs PNP vs NAMUR and Their Roles as Hard Limits, Reference Switches and Tool Presence Sensors-CNCShare | 数控电气技术中心

Inductive Proximity Switches for CNC Machines: NPN vs PNP vs NAMUR and Their Roles as Hard Limits, Reference Switches and Tool Presence Sensors

Inductive proximity switches in three CNC roles - hard limit, reference switch and tool presence - with different selection rules for each. Covers why PNP suits new sourcing-input ...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
0566
FANUC SV0381/0384/0385/0386/0387 Servo Alarms: Poor Grounding and the Linear Scale (EXT) Alarm Family-CNCShare | 数控电气技术中心

FANUC SV0381/0384/0385/0386/0387 Servo Alarms: Poor Grounding and the Linear Scale (EXT) Alarm Family

On a full-closed-loop machine SV0381/0384/0385/0386/0387 often trip alternately or keep repeating on one axis, easily misread as a broken scale or amplifier. These alarms all say '...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
04713
Bypassing a FANUC Linear Scale: Full to Semi Closed-Loop Conversion with 1815#1, 2024, 2084/2085 and 2185-CNCShare | 数控电气技术中心

Bypassing a FANUC Linear Scale: Full to Semi Closed-Loop Conversion with 1815#1, 2024, 2084/2085 and 2185

How to temporarily bypass a FANUC linear scale and switch from full to semi closed-loop: 1815#1/#5, 2024, 2084/2085, 2185, 1821, 1850, 1851/1852, 2003#5 and 2019#7. Marks the dispu...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare5天前
04415