排序
Fanuc System Alarms 950, 971, 974: Meaning and Board-Level Diagnosis
Fanuc system alarms 900–976 in one table: 900 ROM PARITY, 910–919 memory parity, 920/921 axis cards, 926 FSSB, 930 CPU, 935 SRAM ECC, 950/951 PMC with the PCxxx detail code, 970...
FANUC Spindle Amplifier Alarm Codes 01-88 (SPM/PSM) and First Checks
Reading the two digits on the spindle amp LED? This full list maps FANUC SPM alarm codes 01–88 and A/b0/C0 letter codes to plain-English meaning, first action, and how to tell whe...
Fanuc E-Stop Circuit: G8.4, X8.4 Signals and Why the Servo Is Not Ready
Releasing the E-stop does not bring the servo back, and the control often gives no alarm number. Walks the four-layer chain: 24V safety loop, X8.4, G8.4, SA / MCC / CX4, with an X-...
FANUC SERVO GUIDE: Waveform Analysis, Vibration Suppression and Rigid Tapping
A field guide to FANUC SERVO GUIDE: what it does, which controls it supports, how to install and connect over Ethernet, and the four workflows that solve most servo problems.
How to Classify and Troubleshoot CNC Homing Failures: Reference Not Found vs Wrong Reference Position + Decel Dog / One-Turn Signal + Grid Shift 1850 / Reference Counter 1821 + Absolute Encoder Battery
Stop swapping parts to see what sticks. Split homing failures into two classes: reference not found, and reference position wrong. In the first class, watch whether the axis decele...
Fanuc Gravity-Axis Brake: Release Sequence, 24V Wiring and Diagnosing Z-Axis Drop
A Z axis that drops on E-stop or power loss is not simply a bad brake. Based on FANUC B-65162E/03-10: power-off engaged brake, power-up/down sequence, dedicated 24V circuit, BRKC, ...
Fanuc Backlash Compensation 1851: Measure, Convert to Detection Units, Write and Verify
The complete FANUC backlash compensation procedure: measure with a dial indicator at cutting feed and rapid, convert to detection units (0.020 mm becomes 20; lathe X axis times 2),...
FANUC Servo Amplifier Replacement: Power-Off and Discharge, Teardown Order, Motor ID No.2020 Write-Back, Three Post-Swap Checks
A complete FANUC servo amplifier replacement procedure following official αi / βi parameter wording: the repair-or-replace decision, cutting main power (not the E-stop) and waiti...
Replacing a FANUC Servo Motor: Parameters 2020, 2022 and 2021, Re-measuring Inertia and Re-verifying Compensation
FANUC servo motor replacement explained: amplifier swap versus motor swap, a correction to motor-side parameters (2021 inertia ratio, 2023 velocity pulses, 1825 position loop gain,...
FANUC Alarm History and Operation History: Using 3106#4 OPH to Trace Intermittent Faults
Intermittent faults cannot be reproduced on demand, so the only evidence is the timeline. Based on the official FANUC maintenance manual, this guide covers 3106#4 OPH, 3106#7 OHS, ...