English 第9页
FANUC / CNC technical articles in English
Looking for a curated starting point instead of the full post list? → FANUC & CNC Troubleshooting Guides (English) groups every English article by topic with a FAQ.
Spindle Unclamp Failure / Tool Not Seated: Air Supply, PMC Inputs and Signal Chain-CNCShare | 数控电气技术中心

Spindle Unclamp Failure / Tool Not Seated: Air Supply, PMC Inputs and Signal Chain

Do not strip the drawbar first. Trace the eight-stage chain from the pressure switch through PMC inputs, ladder conditions, solenoid outputs and seat confirmation, then check ISO 8...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare7天前
0669
Five Peripheral Alarm Clusters on CNC Machines: Coolant, Lubrication, Chip Conveyor, Air and Hydraulics - From English Alarm Text to PMC Feedback to Action-CNCShare | 数控电气技术中心

Five Peripheral Alarm Clusters on CNC Machines: Coolant, Lubrication, Chip Conveyor, Air and Hydraulics – From English Alarm Text to PMC Feedback to Action

Coolant, lubrication, chip conveyor, pneumatic and hydraulic alarms are usually written by the machine tool builder in the PMC/PLC, not by FANUC or Siemens. A cross-system matrix o...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare7天前
02912
CNC Alarm Message Chinese Reference: 120 Common English Phrases and a 30-Second Triage Method-CNCShare | 数控电气技术中心

CNC Alarm Message Chinese Reference: 120 Common English Phrases and a 30-Second Triage Method

Translating an English alarm is only the first step. This page groups 120 common field phrasings by subsystem with Chinese meanings, maps keywords such as NOT READY, OVERLOAD, FAUL...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare7天前
05710
How to Export / Print FANUC Parameter Tables and Ladder Programs: One-Click Backup, BOOT SRAM Backup and PMC Ladder to Card-CNCShare | 数控电气技术中心

How to Export / Print FANUC Parameter Tables and Ladder Programs: One-Click Backup, BOOT SRAM Backup and PMC Ladder to Card

FANUC backup has three routes: the 0i-F / 0i-F Plus one-click full backup runs in two stages and needs one power cycle; the BOOT-screen SRAM backup starts before the NC, needs no p...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare8天前
0975
"FANUC Data Backup and Recovery: ALL I/O Full Backup vs BOOT SRAM Backup — 3 Methods Compared + Restore Steps"-CNCShare | 数控电气技术中心

“FANUC Data Backup and Recovery: ALL I/O Full Backup vs BOOT SRAM Backup — 3 Methods Compared + Restore Steps”

'FANUC data backup explained: when to use ALL I/O one-click full backup (0i-F / 0i-F Plus), BOOT SRAM backup (system won't boot), or itemized backup. Covers parameters 0020 / 0313#...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare8天前
0926
Refurbished vs New FANUC Servo Amplifier: Cost Comparison and Repair-or-Replace Decision Table-CNCShare | 数控电气技术中心

Refurbished vs New FANUC Servo Amplifier: Cost Comparison and Repair-or-Replace Decision Table

Comparing repair cost against new-part cost is the wrong way to decide. This guide covers repairability assessment, three tiers of repair, three replacement options, and a four-fac...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare8天前
0425
Fanuc CNC Specifications Comparison: 0i-MF vs 30i-B vs 31i-B vs 32i-B vs 35i-B, Two Official Data Sets-CNCShare | 数控电气技术中心

Fanuc CNC Specifications Comparison: 0i-MF vs 30i-B vs 31i-B vs 32i-B vs 35i-B, Two Official Data Sets

Is the 30i-B a 96-axis or a 40-axis control? Both figures are official, from two generations of Fanuc literature. Two data sets side by side, a fourteen-item verification framework...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare8天前
05112
GSK CNC Alarm Code Reference: 980T / 980TD / 988T / 988TA Number Ranges and PLC Alarms 1000-1037 with A-Addresses-CNCShare | 数控电气技术中心

GSK CNC Alarm Code Reference: 980T / 980TD / 988T / 988TA Number Ranges and PLC Alarms 1000-1037 with A-Addresses

Search results for GSK alarm codes are dominated by English sites. This page verifies the framework against the GSK988T User Manual Appendix A.8 and the 980TDb standard ladder: 980...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare8天前
0685
Fanuc Alarm, Parameter and Diagnostic Cross-Reference Table: Verified SV / PS / OH Anchors and the Two Numbering Generations-CNCShare | 数控电气技术中心

Fanuc Alarm, Parameter and Diagnostic Cross-Reference Table: Verified SV / PS / OH Anchors and the Two Numbering Generations

You have a Fanuc alarm number - what next? This page turns the three-way mapping of alarm number, parameter number and diagnostic number into a framework table: the alarm is the sy...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare8天前
03813
Fanuc 0i-B / 0i-C Legacy Alarms: Same Number, Different Board - 920 / 930 / 950 / 974 / 975 Decoded-CNCShare | 数控电气技术中心

Fanuc 0i-B / 0i-C Legacy Alarms: Same Number, Different Board – 920 / 930 / 950 / 974 / 975 Decoded

On a 0i-B or 0i-C the alarms are plain numbers with no SV/PS prefix, and a 920 does not point to the same hardware as on a 0i-D/0i-F. The 900 range verified against manual B-64115E...
cncshare的头像-CNCShare | 数控电气技术中心钻石会员cncshare8天前
04214