cncshare的头像-CNCShare | 数控电气技术中心
共享屋江苏管理员
每天进步一点点
SINUMERIK Servo Alarms 25000, 25010 and 25201: Which Layer to Troubleshoot First-CNCShare | 数控电气技术中心

SINUMERIK Servo Alarms 25000, 25010 and 25201: Which Layer to Troubleshoot First

SINUMERIK three-code triage: 25000/25010 are NCK measuring-system alarms, while 25201 is the NC relaying a SINAMICS drive fault whose real cause is a drive-side F code. Includes a ...
4天前
05613
海德汉 TNC 错误码对照表:6 位码怎么读 + 120/125/130/140/230 各族高频码逐条解-CNCShare | 数控电气技术中心

海德汉 TNC 错误码对照表:6 位码怎么读 + 120/125/130/140/230 各族高频码逐条解

海德汉 TNC 错误码中文对照:六位码制(三位族号+四位十六进制序号)读法、120/125/130/140/145/160/1A0/201/230/231/280/320 全族谱与 NC 侧/机床厂侧分界、120-001E/001F/130-00A7/160-008B/2...
Inductive Proximity Switches for CNC Machines: NPN vs PNP vs NAMUR and Their Roles as Hard Limits, Reference Switches and Tool Presence Sensors-CNCShare | 数控电气技术中心

Inductive Proximity Switches for CNC Machines: NPN vs PNP vs NAMUR and Their Roles as Hard Limits, Reference Switches and Tool Presence Sensors

Inductive proximity switches in three CNC roles - hard limit, reference switch and tool presence - with different selection rules for each. Covers why PNP suits new sourcing-input ...
4天前
0566
FANUC Matrix Keypad Panel Replacement: Remapping PMC Ladder Logic and Resolving R-Address Conflicts-CNCShare | 数控电气技术中心

FANUC Matrix Keypad Panel Replacement: Remapping PMC Ladder Logic and Resolving R-Address Conflicts

FANUC Matrix Keypad Panel Replacement: Remapping PMC Ladder Logic and Resolving R-Address Conflicts Field notes by 共享屋 (Gongxiangwu) — a real panel-swap job, compiled from wech...
FANUC 0i-B / 0i-C 老系统报警速查:同号异义 + 920/930/950 换板还是查线-CNCShare | 数控电气技术中心

FANUC 0i-B / 0i-C 老系统报警速查:同号异义 + 920/930/950 换板还是查线

0i-B / 0i-C 用裸号段,同一个 920 在新代指向不同部件。本页按 0i-C 维护手册 B-64115EN/02 逐条核实 900 段:950 在老代是熔丝而非 PMC,只有 975 用 ADRS 定位,附换板顺序与电池更换时限。
Mitsubishi M80 Magazine Scrambled Quick Chart: Symptom, Tool Registration Fields and R Registers-CNCShare | 数控电气技术中心

Mitsubishi M80 Magazine Scrambled Quick Chart: Symptom, Tool Registration Fields and R Registers

One page for a scrambled Mitsubishi M80 magazine: match the symptom, then act. Spindle sync, the four Tool Registration targets, and the magazine / tool-life R-register addresses a...
22天前
0559
FANUC Parameter Write Protect (PWE): How to Unlock Parameters, SW0100, and the 3210/3211 vs 3202#4 NE9 Mix-Up-CNCShare | 数控电气技术中心

FANUC Parameter Write Protect (PWE): How to Unlock Parameters, SW0100, and the 3210/3211 vs 3202#4 NE9 Mix-Up

Four independent locks can stop you editing a FANUC control. This guide gives the MDI to SETTING to PWE path, explains why SW0100 is only a status message, and corrects the widespr...
8天前
05513
FANUC 固定循环怎么用?G81 / G82 / G83 / G73 / G84 / G85 / G86 / G87 / G88 九个循环一张表选对 + Q/R/P/K 地址字 + 参数 5121/5213 + 045 报警根因-CNCShare | 数控电气技术中心

FANUC 固定循环怎么用?G81 / G82 / G83 / G73 / G84 / G85 / G86 / G87 / G88 九个循环一张表选对 + Q/R/P/K 地址字 + 参数 5121/5213 + 045 报警根因

固定循环是 FANUC 编程里一行代码干一串动作的功能,也是新手最容易出事的地方。本篇讲清三个模态 G90/G91、G98/G99、G80 的区别,九个循环 G81-G88 的选用,Q/R/P/K 地址字写法,G73 与 G83 的...
How to Clear All Parameters on a Fanuc Control: RESET + DELETE Power-On Sequence Explained (and Why "Restore Factory Settings" Does Not Exist)-CNCShare | 数控电气技术中心

How to Clear All Parameters on a Fanuc Control: RESET + DELETE Power-On Sequence Explained (and Why “Restore Factory Settings” Does Not Exist)

A good half of the 'Fanuc restore factory settings' tutorials are wrong: there is no such menu on a 0i-MD / 0i-MF. The real entry is a hardware key combo - power down, hold RESET +...
8天前
0546
Fanuc Pitch Error Compensation 3620-3624: Laser Measurement, Point Numbering and Parameter Entry-CNCShare | 数控电气技术中心

Fanuc Pitch Error Compensation 3620-3624: Laser Measurement, Point Numbering and Parameter Entry

The complete FANUC pitch error compensation procedure: cross-generation parameter table (0M 0712-0715/1000-1128 vs i-series 3620-3624 vs 16i/18i bidirectional 3605#0/3626/3627), la...
3天前
05410