加工尺寸忽大忽小怎么查?四条线分离法:机械线 / 检测反馈线 / 工艺刀具线 / 数据基准线,一次把波动源分开
尺寸忽大忽小别再靠反复调刀补硬压 —— 刀补只修稳定的系统偏差,修不了随机漂移。用四条线分离法先判断「变化跟着什么走」:随件数走是刀具磨损,随时间走是热变形,随位置走是丝杠/螺距,随...
Machine Safety Circuits: STO vs SS1, Stop Categories, PL / SIL, Dual Channels and EDM
A circulating brief attributes Cat0 / Cat1 / Cat2 / Cat3 to ISO 13849. That merges two different meanings of category: stop categories 0/1/2 come from IEC 60204-1, architecture cat...
海德汉 TNC「防护门未关 / 门未关」报警怎么查:安全链四层定位 + 门开关门锁排查 + 改动后四项验证
海德汉 TNC 报「防护门未关 / DOOR OPEN / GUARD NOT CLOSED」,本质不是 NC 软件故障,而是 PLC 把「门关闭条件」判成 false。本文按安全链四层(门开关机械 → 安全继电器 → PLC 数字量输入 ...
Fanuc Servo Load Meter Explained: Bands, 3111 Switches and Diagnostics 200-204 / 300
POS monitor for patrol, SV monitor for decisions, diagnostics for causes. Covers what 'actual current (%)' really means, peaks versus sustained load, and two common parameter-bit m...
海德汉 TCH PROBE 31/481 测刀循环参数对照:iTNC530 走 MP、TNC640 走 Cfg,逐齿上限 99 与 20 的分界
对刀仪测刀测不准,根子多在循环格式选错代、安全区参数找错地方、TOOL.T 该预填的字段空着。本文按官方手册口径讲透 TCH PROBE 31 与 481 的两代格式差异、Q340 覆写/比较/只读三模式、Q260 安...
FANUC PMC Functional Instruction (SUB) Quick Reference: Numbers, Families and Model Availability
PMC functional instructions are called by SUB number, but the same SUB number is not available on every PMC model. Verifiable SUB numbers and families from official Table 5(a), rea...
Spindle Runout: Four-Layer Diagnosis, the Two-Point Test Arbor Split and Taper Contact Pattern Checking
Runout guides publish a single universal tolerance and diagnose every far-point reading as a bearing preload problem. The two-point reading only gives a direction, and published so...
HEIDENHAIN TNC Conversational Programming for Beginners: One Minimal Program
HEIDENHAIN Klartext is conversational programming - the screen asks, you answer, no G-code memorising. Using a 13-line minimal program, this explains BEGIN PGM, BLK FORM blank, TOO...
Fanuc Tool Setter / Probe Calibration: Parameters 5015-5018, G31 / G36 / G37 and the O9000 Macro Chain
Parameters 5015 and 5016 are not ID and OD tools. The official Fanuc additional manual defines four contact surfaces. Four reference distances, a six-step field calibration, skip v...
HEIDENHAIN TNC Generation Cross-Reference: MP vs Cfg, Model Differences and Cycle Compatibility
One-page lookup for iTNC 530 / TNC 620 / TNC 640 / TNC7: positioning, control loops, NC software numbers, MP vs Cfg parameter systems, and the MP-to-Cfg mappings HEIDENHAIN officia...